CoChat

Operating a treatment planning system using a deep‐reinforcement learning‐based virtual treatment planner for prostate cancer intensity‐modulated radiation therapy treatment planning

Open access
Shen, Chenyang, Nguyen, Dan, Chen, Liyuan, Gonzalez, Yesenia, McBeth, Rafe, Qin, Nan, Jiang, Steve B., Jia, Xun · 2020 · Medical Physics
Cited by 101

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Purpose: In the treatment planning process of intensity‐modulated radiation therapy (IMRT), a human planner operates the treatment planning system (TPS) to adjust treatment planning parameters, for example, dose volume histogram (DVH) constraints’ locations and weights, to achieve a satisfactory plan for each patient. This process is usually time‐consuming, and the plan quality depends on planer’s experience and available planning time. In this study, we proposed to model the behaviors of human planners in treatment planning by a deep reinforcement learning (DRL)‐based virtual treatment planner network (VTPN), such that it can operate the TPS in a human‐like manner for treatment planning. Methods and Materials: Using prostate cancer IMRT as an example, we established the VTPN using a deep neural network developed. We considered an in‐house optimization engine with a weighted quadratic objective function. Virtual treatment planner network was designed to observe an intermediate plan DVHs and decide the action to improve the plan by changing weights and threshold dose in the objective function. We trained the VTPN in an end‐to‐end DRL process in 10 patient cases. A plan score was used to measure plan quality. We demonstrated the feasibility and effectiveness of the trained VTPN in another 64 patient cases. Results: Virtual treatment planner network was trained to spontaneously learn how to adjust treatment planning parameters to generate high‐quality treatment plans. In the 64 testing cases, with initialized parameters, quality score was 4.97 (±2.02), with 9.0 being the highest possible score. Using VTPN to perform treatment planning improved quality score to 8.44 (±0.48). Conclusions: To our knowledge, this was the first time that intelligent treatment planning behaviors of human planner in external beam IMRT are autonomously encoded in an artificial intelligence system. The trained VTPN is capable of behaving in a human‐like way to produce high‐quality plans.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mp.14114

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

Metadata

Authors
Shen, C., Nguyen, D., Chen, L., Gonzalez, Y., McBeth, R., Qin, N., Jiang, S. B., & Jia, X.
Venue
Medical Physics
Publisher
Wiley
Published
2020-03-28
Volume
47
Issue
6
Pages
2329-2336
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W3010456886
Cited by
101
References
7
FWCI
8.34
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.