Does FLASH deplete oxygen? Experimental evaluation for photons, protons, and carbon ions
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Purpose: To investigate experimentally, if FLASH irradiation depletes oxygen within water for different radiation types such as photons, protons, and carbon ions. Methods: This study presents measurements of the oxygen consumption in sealed, 3D‐printed water phantoms during irradiation with x‐rays, protons, and carbon ions at varying dose rates up to 340 Gy/s. The oxygen measurement was performed using an optical sensor allowing for noninvasive measurements. Results: Oxygen consumption in water only depends on dose, dose rate, and linear energy transfer (LET) of the irradiation. The total amount of oxygen depleted per 10 Gy was found to be 0.04% atm ‐ 0.18% atm for 225 kV photons, 0.04% atm ‐ 0.25% atm for 224 MeV protons, and 0.09% atm ‐ 0.17% atm for carbon ions. Consumption depends on dose rate by an inverse power law and saturates for higher dose rates because of self‐interactions of radicals. Higher dose rates yield lower oxygen consumption. No total depletion of oxygen was found for clinical doses. Conclusions: FLASH irradiation does consume oxygen, but not enough to deplete all the oxygen present. For higher dose rates, less oxygen was consumed than at standard radiotherapy dose rates. No total depletion was found for any of the analyzed radiation types for 10 Gy dose delivery using FLASH.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Favaudon, V., Caplier, L., Monceau, V., Pouzoulet, F., Sayarath, M., Fouillade, C., Poupon, M.-F., Brito, I., Hupé, P., Bourhis, J., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008973 · Cited by 1,476
Why is the partial oxygen pressure of human tissues a crucial parameter? Small molecules and hypoxia
Carreau, A., Hafny‐Rahbi, B. E., Matejuk, A., Grillon, C., & Kieda, C. (2011) · Journal of Cellular and Molecular Medicine · doi:10.1111/j.1582-4934.2011.01258.x · Cited by 1,246
Ultra-High Dose Rate (FLASH) Radiotherapy: Silver Bullet or Fool's Gold?
Wilson, J. D., Hammond, E. M., Higgins, G. S., & Petersson, K. (2020) · Frontiers in Oncology · doi:10.3389/fonc.2019.01563 · Cited by 473
Roots, R., & Okada, S. (1975) · Radiation Research · doi:10.2307/3574267 · Cited by 429
Roots, R., & Okada, S. (1975) · PubMed · Cited by 419
Physics and biology of ultrahigh dose-rate (FLASH) radiotherapy: a topical review
Esplen, N., Mendonca, M. S., & Bazalova-Carter, M. (2020) · Physics in Medicine & Biology · doi:10.1088/1361-6560/abaa28 · Cited by 270
Labarbe, R., Hotoiu, L., Barbier, J., & Favaudon, V. (2020) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2020.06.001 · Cited by 206
Kill-painting of hypoxic tumours in charged particle therapy
Tinganelli, W., Durante, M., Hirayama, R., Krämer, M., Maier, A., Kraft-Weyrather, W., Furusawa, Y., Friedrich, T., & Scifoni, E. (2015) · Scientific Reports · doi:10.1038/srep17016 · Cited by 167
A Quantitative Analysis of the Role of Oxygen Tension in FLASH Radiation Therapy
Petersson, K., Adrian, G., Butterworth, K. T., & McMahon, S. J. (2020) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2020.02.634 · Cited by 156
Mattei, G., Ferretti, C., Tirella, A., Ahluwalia, A., & Mattioli-Belmonte, M. (2015) · Scientific Reports · doi:10.1038/srep14590 · Cited by 147
Cited by
Towards clinical translation of FLASH radiotherapy
Vozenin, M.-C., Bourhis, J., & Durante, M. (2022) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-022-00697-z · Cited by 363
Radiobiology of the FLASH effect
Friedl, A. A., Prise, K. M., Butterworth, K. T., Montay‐Gruel, P., & Favaudon, V. (2022) · Medical Physics · doi:10.1002/mp.15184 · Cited by 203
Metadata
- Authors
- Jansen, J., Knoll, J., Beyreuther, E., Pawelke, J., Skuza, R., Hanley, R., Brons, S., Pagliari, F., & Seco, J.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2021-05-27
- Volume
- 48
- Issue
- 7
- Pages
- 3982-3990
- ISSN
- 2331-8422 (ISSN-L)
- 0094-2405
- 2473-4209
- OpenAlex
- W3159708250
- Cited by
- 164
- References
- 18
- Type
- posted content
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Does FLASH deplete oxygen? Experimental evaluation for photons, protons, and carbon ions. https://app.cochat.ai/papers/10.1002/mp.14917
- The paper
- Jansen, J., Knoll, J., Beyreuther, E., Pawelke, J., Skuza, R., Hanley, R., Brons, S., Pagliari, F., & Seco, J. (2021). Does FLASH deplete oxygen? Experimental evaluation for photons, protons, and carbon ions. Medical Physics. https://doi.org/10.1002/mp.14917
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.