AAPM task group report 302: Surface‐guided radiotherapy
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
The clinical use of surface imaging has increased dramatically, with demonstrated utility for initial patient positioning, real‐time motion monitoring, and beam gating in a variety of anatomical sites. The Therapy Physics Subcommittee and the Imaging for Treatment Verification Working Group of the American Association of Physicists in Medicine commissioned Task Group 302 to review the current clinical uses of surface imaging and emerging clinical applications. The specific charge of this task group was to provide technical guidelines for clinical indications of use for general positioning, breast deep‐inspiration breath hold treatment, and frameless stereotactic radiosurgery. Additionally, the task group was charged with providing commissioning and on‐going quality assurance (QA) requirements for surface‐guided radiation therapy (SGRT) as part of a comprehensive QA program including risk assessment. Workflow considerations for other anatomic sites and for computed tomography simulation, including motion management, are also discussed. Finally, developing clinical applications, such as stereotactic body radiotherapy (SBRT) or proton radiotherapy, are presented. The recommendations made in this report, which are summarized at the end of the report, are applicable to all video‐based SGRT systems available at the time of writing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The management of respiratory motion in radiation oncology report of AAPM Task Group 76a)
Keall, P. J., Mageras, G. S., Balter, J. M., Emery, R. S., Forster, K. M., Jiang, S. B., Kapatoes, J. M., Low, D. A., Murphy, M. J., Murray, B. R., et al. (2006) · Medical Physics · doi:10.1118/1.2349696 · Cited by 2,327
van Herk, M., Remeijer, P., Rasch, C., & Lebesque, J. V. (2000) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(00)00518-6 · Cited by 1,531
Huq, M. S., Fraass, B. A., Dunscombe, P., Gibbons, J. P., Ibbott, G. S., Mundt, A. J., Mutic, S., Palta, J. R., Rath, F., Thomadsen, B., et al. (2016) · Medical Physics · doi:10.1118/1.4947547 · Cited by 607 · cited 6×
“Two main challenges were encountered in the initial phase of implementing SGRT for head and neck: (1) obstruction of the patient’s surface by traditional closed full-face immobilization masks and (2) influence on registration accuracy from routine physiologic processes, such as swallowing and blinking.”
BackgroundMethodInfluentialAAPM task group 224: Comprehensive proton therapy machine quality assurance
Arjomandy, B., Taylor, P., Ainsley, C., Safai, S., Sahoo, N., Pankuch, M., Farr, J. B., Yong Park, S., Klein, E., Flanz, J., et al. (2019) · Medical Physics · doi:10.1002/mp.13622 · Cited by 229
AAPM ‐ RSS Medical Physics Practice Guideline 9.a. for SRS ‐ SBRT
Halvorsen, P. H., Cirino, E. T., Das, I. J., Garrett, J. A., Yang, J., Yin, F.-F., & Fairobent, L. A. (2017) · Journal of Applied Clinical Medical Physics · doi:10.1002/acm2.12146 · Cited by 218
Bartlett, F. R., Colgan, R. M., Carr, K., Donovan, E. M., McNair, H. A., Locke, I., Evans, P. M., Haviland, J. S., Yarnold, J. R., & Kirby, A. M. (2013) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2013.04.021 · Cited by 208
Swanson, T., Grills, I. S., Ye, H., Entwistle, A., Teahan, M., Letts, N., Yan, D., Duquette, J., & Vicini, F. A. (2013) · American Journal of Clinical Oncology · doi:10.1097/coc.0b013e31823fe481 · Cited by 159
The Role of Optical Surface Imaging Systems in Radiation Therapy
Hoisak, J. D. P., & Pawlicki, T. A. (2018) · Seminars in Radiation Oncology · doi:10.1016/j.semradonc.2018.02.003 · Cited by 152
Self-citationSchönecker, S., Walter, F., Freislederer, P., Marisch, C., Scheithauer, H., Harbeck, N., Corradini, S., & Belka, C. (2016) · Radiation Oncology · doi:10.1186/s13014-016-0716-5 · Cited by 122
Microsoft Kinect Visual and Depth Sensors for Breathing and Heart Rate Analysis
Procházka, A., Schätz, M., Vyšata, O., & Vališ, M. (2016) · Sensors · doi:10.3390/s16070996 · Cited by 86
Cited by
ESTRO-EANO guideline on target delineation and radiotherapy details for glioblastoma
Niyazi, M., Andratschke, N., Bendszus, M., Chalmers, A. J., Erridge, S. C., Galldiks, N., Lagerwaard, F. J., Navarria, P., Munck af Rosenschöld, P., Ricardi, U., et al. (2023) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2023.109663 · Cited by 232
“Surface-guided radiotherapy in combination with X-ray imaging has shown sub-millimetric accuracy in several studies [52].”
Artificial intelligence in radiotherapy
Li, G., Wu, X., & Ma, X. (2022) · Seminars in Cancer Biology · doi:10.1016/j.semcancer.2022.08.005 · Cited by 46
Metadata
- Authors
- Al‐Hallaq, H. A., Cerviño, L., Gutierrez, A. N., Havnen‐Smith, A., Higgins, S. A., Kügele, M., Padilla, L., Pawlicki, T., Remmes, N., Smith, K., Tang, X., & Tomé, W. A.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2022-03-15
- Volume
- 49
- Issue
- 4
- Pages
- e82-e112
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W4212859994
- Cited by
- 208
- References
- 34
- FWCI
- 27.34
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: AAPM task group report 302: Surface‐guided radiotherapy. https://app.cochat.ai/papers/10.1002/mp.15532
- The paper
- Al‐Hallaq, H. A., Cerviño, L., Gutierrez, A. N., Havnen‐Smith, A., Higgins, S. A., Kügele, M., Padilla, L., Pawlicki, T., Remmes, N., Smith, K., Tang, X., & Tomé, W. A. (2022). AAPM task group report 302: Surface‐guided radiotherapy. Medical Physics. https://doi.org/10.1002/mp.15532
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.