Heating caused by radiofrequency irradiation and sample rotation in 13C magic angle spinning NMR studies of lipid membranes
The DOI matches its Crossref record.
Abstract
Application of rapid sample rotation and radiofrequency irradiation in magic angle spinning (MAS) NMR of lipid bilayers can significantly increase the sample temperature. In this work, we studied the extent of heating during the acquisition of 1 H‐decoupled 13 C MAS spectra of hydrated dimyristoylphosphatidylcholine (DMPC) in the L α phase. First, we describe a simple procedure for determining the increase in temperature by observing the shift of the 1 H water signal. The method is then used to identify and assess the various factors that contribute to the sample heating. The important factors discussed in this paper include: (i) the spinning speed, (ii) the variable‐temperature gas pressure, (iii) the rotor geometry, (iv) the power, duration and frequency of the radiofrequency irradiation and (v) the hydration level. A comparison of different heteronuclear decoupling schemes in terms of their ability to produce highly resolved 13 C spectra of DMPC is also reported. Copyright © 2004 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Solid-state NMR experiments in conductive and dielectrically lossy protein samples are hindered by significant sample heating from high-frequency irradiation during cross-polarization (CP) and decoupling pulses [1-3].”
From Using low-E resonators to reduce RF heating in biological samples for static solid-state NMR up to 900MHz (2007) · cites this paper as [2]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 48
- 10.1021/ja962951b · DOI
- 10.1016/S0006-3495(98)74055-X · DOI
- 10.1016/S0009-3084(02)00024-5 · DOI
- 10.1016/S1090-7807(02)00067-8 · doi:10.1016/s1090-7807(02)00067-8
- 10.1021/ar00138a003 · DOI
- 10.1126/science.6740310 · doi:10.1126/science.6740310
- 10.1016/S0066-4103(00)41010-0 · DOI
- Levitt MH, 2002, Encyclopedia of Nuclear Magnetic Resonance, 165
- 10.1021/ac00127a056 · doi:10.1021/ac00127a056
- 10.1016/0022-2364(89)90020-6 · doi:10.1016/0022-2364(89)90020-6
- 10.1016/0022-2364(90)90315-Z · doi:10.1016/0022-2364(90)90315-z
- 10.1006/jmra.1993.1046 · doi:10.1006/jmra.1993.1046
- 10.1016/0926-2040(95)01189-1 · doi:10.1016/0926-2040(95)01189-1
- 10.1006/jmra.1995.0010 · doi:10.1006/jmra.1995.0010
- 10.1016/S0009-3084(97)00082-0 · doi:10.1016/s0009-3084(97)00082-0
- 10.1016/S0926-2040(00)00061-8 · DOI
- 10.1002/mrc.924 · doi:10.1002/mrc.924
- Samoson A, 2002, Encyclopedia of Nuclear Magnetic Resonance, 59
- 10.1016/0022-2364(78)90069-0 · DOI
- 10.1016/0022-2364(79)90023-4 · DOI · Paper page
- 10.1016/0022-2364(79)90019-2 · DOI · Paper page
- Chen C‐N, 1989, Biomedical Magnetic Resonance Technology, 117
- Spooner PJR, 1990, J. Magn. Reson., 90, 584
- 10.1006/jmra.1994.1208 · DOI · Paper page
- 10.1039/f19888403821 · DOI
- 10.1063/1.1726676 · DOI · Paper page
- 10.1063/1.1744199 · doi:10.1063/1.1744199
- 10.1002/nbm.1940070508 · doi:10.1002/nbm.1940070508
- 10.1002/1522-2594(200006)43:6<796::AID-MRM4>3.0.CO;2-2 · doi:10.1002/1522-2594(200006)43:6<796::aid-mrm4>3.0.co;2-2
- 10.1063/1.1576753 · doi:10.1063/1.1576753
- Doty FD, 1996, Encyclopedia of Nuclear Magnetic Resonance, 3753
- Khitrin AK, 2002, Encyclopedia of Nuclear Magnetic Resonance, 91
- 10.1006/jmre.1997.1322 · doi:10.1006/jmre.1997.1322
- 10.1006/jmre.1999.1896 · DOI · Paper page
- 10.1016/S1090-7807(03)00074-0 · DOI
- 10.1063/1.470372 · DOI · Paper page
- 10.1016/0022-2364(87)90228-9 · DOI
- 10.1016/0009-2614(91)90268-E · DOI
- 10.1006/jmre.1999.1907 · doi:10.1006/jmre.1999.1907
- Fung BM, 1990, J. Magn. Reson., 86, 160
- Fung BM, 1996, Encyclopedia of Nuclear Magnetic resonance, 2744
- 10.1063/1.481281 · DOI · Paper page
- 10.1016/S1090-7807(03)00180-0 · DOI
- 10.1021/bi00607a006 · DOI · Paper page
- 10.1016/S1090-7807(02)00182-9 · doi:10.1016/s1090-7807(02)00182-9
- 10.1016/0022-2364(86)90118-6 · doi:10.1016/0022-2364(86)90118-6
- 10.1016/S1090-7807(02)00120-9 · doi:10.1016/s1090-7807(02)00120-9
- PamarthyK KulkarniJ EntzmingerG ShevgoorS XiaoC GravelJ HolteLL ShinoharaJ StaabJP DotyFD. Presented at the 45th ENC Conference Pacific Grove CA 2004.
Cited by
Gor’kov, P. L., Chekmenev, E. Y., Li, C., Cotten, M., Buffy, J. J., Traaseth, N. J., Veglia, G., & Brey, W. W. (2007) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2006.11.008 · Cited by 213
Metadata
- Authors
- Dvinskikh, S. V., Castro, V., & Sandström, D.
- Venue
- Magnetic Resonance in Chemistry
- Publisher
- Wiley
- Published
- 2004-08-31
- Volume
- 42
- Issue
- 10
- Pages
- 875-881
- ISSN
- 0749-1581
- 1097-458X
- Cited by
- 72
- References
- 0
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.