The DOI matches its Crossref record.
Further Conventions for NMR Shielding and Chemical Shifts (IUPAC Recommendations 2008): International Union of Pure and Applied Chemistry Physical and Biophysical Chemistry Division
Abstract
IUPAC has published a number of recommendations regarding the reporting of nuclear magnetic resonance (NMR) data, especially chemical shifts. The most recent publication [Pure Appl. Chem. 73, 1795 (2001)] recommended that tetramethylsilane (TMS) serve as a universal reference for reporting the shifts of all nuclides, but it deferred recommendations for several aspects of this subject. This document first examines the extent to which the 1 H shielding in TMS itself is subject to change by variation in temperature, concentration, and solvent. On the basis of recently published results, it has been established that the shielding of TMS in solution [along with that of sodium‐3‐(trimethylsilyl)propanesulfonate, DSS, often used as a reference for aqueous solutions] varies only slightly with temperature but is subject to solvent perturbations of a few tenths of a part per million (ppm). Recommendations are given for reporting chemical shifts under most routine experimental conditions and for quantifying effects of temperature and solvent variation, including the use of magnetic susceptibility corrections and of magic‐angle spinning (MAS). This document provides the first IUPAC recommendations for referencing and reporting chemical shifts in solids, based on high‐resolution MAS studies. Procedures are given for relating 13 C NMR chemical shifts in solids to the scales used for high‐resolution studies in the liquid phase. The notation and terminology used for describing chemical shift and shielding tensors in solids are reviewed in some detail, and recommendations are given for best practice. © 2008 IUPAC. Reprinted with permission from Pure Appl. Chem. 2008; 80: 59. This article can be freely downloaded from http://www.iupac.org/publications/pac/80/1/0059/ and can be copied, provided acknowledgement to IUPAC is given.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Microbial lipases and their industrial applications: a comprehensive review
Chandra, P., Enespa, Singh, R., & Arora, P. K. (2020) · Microbial Cell Factories · doi:10.1186/s12934-020-01428-8 · Cited by 887
Materials’ Methods: NMR in Battery Research
Pecher, O., Carretero-González, J., Griffith, K. J., & Grey, C. P. (2017) · Chemistry of Materials · doi:10.1021/acs.chemmater.6b03183 · Cited by 452
New insights in polydopamine formation via surface adsorption
Hemmatpour, H., De Luca, O., Crestani, D., Stuart, M. C. A., Lasorsa, A., van der Wel, P. C. A., Loos, K., Giousis, T., Haddadi-Asl, V., & Rudolf, P. (2023) · Nature Communications · doi:10.1038/s41467-023-36303-8 · Cited by 405
Interpreting protein chemical shift data
Wishart, D. S. (2011) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2010.07.004 · Cited by 252
Stevens, A., Shamseer, L., Weinstein, E., Yazdi, F., Turner, L., Thielman, J., Altman, D. G., Hirst, A., Hoey, J., Palepu, A., et al. (2014) · BMJ · doi:10.1136/bmj.g3804 · Cited by 242
Metadata
- Authors
- Harris, R. K., Becker, E. D., De Menezes, S. M. C., Granger, P., Hoffman, R. E., & Zilm, K. W.
- Venue
- Magnetic Resonance in Chemistry
- Publisher
- Wiley
- Published
- 2008-04-14
- Volume
- 46
- Issue
- 6
- Pages
- 582-598
- ISSN
- 0749-1581 (ISSN-L)
- 1097-458X
- OpenAlex
- W1901715948
- Cited by
- 194
- References
- 0
- FWCI
- 1.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Further Conventions for NMR Shielding and Chemical Shifts (IUPAC Recommendations 2008): International Union of Pure and Applied Chemistry Physical and Biophysical Chemistry Division. https://app.cochat.ai/papers/10.1002/mrc.2225
- The paper
- Harris, R. K., Becker, E. D., De Menezes, S. M. C., Granger, P., Hoffman, R. E., & Zilm, K. W. (2008). Further Conventions for NMR Shielding and Chemical Shifts (IUPAC Recommendations 2008): International Union of Pure and Applied Chemistry Physical and Biophysical Chemistry Division. Magnetic Resonance in Chemistry. https://doi.org/10.1002/mrc.2225
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.