Assessment of T1 and T effects in vivo and ex vivo using iron oxide nanoparticles in steady state—dependence on blood volume and water exchange
The DOI matches its Crossref record.
Abstract
Accurate knowledge of the relationship between contrast agent concentration and tissue relaxation is a critical requirement for quantitative assessment of tissue perfusion using contrast‐enhanced MRI. In the present study, using a pig model, the relationship between steady‐state blood concentration levels of an iron oxide nanoparticle with a hydrated diameter of 12 nm (NC100150 Injection) and changes in the transverse and longitudinal relaxation rates (1/T and 1/T1, respectively) in blood, muscle, and renal cortex was investigated at 1.5 T. Ex vivo measurements of 1/T and 1/T1 were additionally performed in whole pig blood spiked with different concentrations of the iron oxide nanoparticle. In renal cortex and muscle, 1/T increased linearly with contrast agent concentration with slopes of 101 ± 22 s−1 mM−1 and 6.5 ± 0.9 s−1 mM−1 (mean ± SD), respectively. In blood, 1/T increased as a quadratic function of contrast agent concentration, with different quadratic terms in the ex vivo vs. the in vivo experiments. In vivo, 1/T1 in blood increased linearly with contrast agent concentration, with a slope (T1‐relaxivity) of 13.9 ± 0.9 s−1 mM−1. The achievable increase in 1/T1 in renal cortex and muscle was limited by the rate of water exchange between the intra‐ and extravascular compartments and the 1/T1‐curves were well described by a two‐compartment water exchange limited relaxation model. Magn Reson Med 47:461–471, 2002. © 2002 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Applications of Magnetic Nanoparticles in Biomedicine
Bárcena, C., Sra, A. K., & Gao, J. (2009) · Nanoscale Magnetic Materials and Applications · doi:10.1007/978-0-387-85600-1_20 · Cited by 2,565
Taylor, A. J., Salerno, M., Dharmakumar, R., & Jerosch-Herold, M. (2016) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2015.11.005 · Cited by 563
Briley-Saebo, K., Bj�rnerud, A., Grant, D., Ahlstrom, H., Berg, T., & Kindberg, G. M. (2004) · Cell and Tissue Research · doi:10.1007/s00441-004-0884-8 · Cited by 235
Self-citationTargeted nanoparticles for detecting and treating cancer
Sunderland, C. J., Steiert, M., Talmadge, J. E., Derfus, A. M., & Barry, S. E. (2006) · Drug Development Research · doi:10.1002/ddr.20069 · Cited by 200
FAIR true‐FISP perfusion imaging of the kidneys
Martirosian, P., Klose, U., Mader, I., & Schick, F. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10709 · Cited by 193
“2 sec, corresponding to the literature (18,19).”
Background
Metadata
- Authors
- Bjørnerud, A., Johansson, L. O., Briley‐Sæbø, K., & Ahlström, H. K.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2002-02-20
- Volume
- 47
- Issue
- 3
- Pages
- 461-471
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2046016797
- Cited by
- 97
- References
- 0
- FWCI
- 7.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessment of T1 and T effects in vivo and ex vivo using iron oxide nanoparticles in steady state—dependence on blood volume and water exchange. https://app.cochat.ai/papers/10.1002/mrm.10066
- The paper
- Bjørnerud, A., Johansson, L. O., Briley‐Sæbø, K., & Ahlström, H. K. (2002). Assessment of T1 and T effects in vivo and ex vivo using iron oxide nanoparticles in steady state—dependence on blood volume and water exchange. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.10066
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.