Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 255

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Analysis of wave behavior in lossy dielectric samples at high field

Yang, Qing X., Wang, Jinghua, Zhang, Xiaoliang, Collins, Christopher M., Smith, Michael B., Liu, Haiying, Zhu, Xiao‐Hong, Vaughan, J. Thomas, Ugurbil, Kamil, Chen, Wei·2002·Magnetic Resonance in Medicine

Abstract

Radiofrequency (RF) field wave behavior and associated nonuniform image intensity at high magnetic field strengths are examined experimentally and numerically. The RF field produced by a 10‐cm‐diameter surface coil at 300 MHz is evaluated in a 16‐cm‐diameter spherical phantom with variable salinity, and in the human head. Temporal progression of the RF field indicates that the standing wave and associated dielectric resonance occurring in a pure water phantom near 300 MHz is greatly dampened in the human head due to the strong decay of the electromagnetic wave. The characteristic image intensity distribution in the human head is the result of spatial phase distribution and amplitude modulation by the interference of the RF traveling waves determined by a given sample‐coil configuration. The numerical calculation method is validated with experimental results. The general behavior of the RF field with respect to the average brain electrical properties in a frequency range of 42–350 MHz is also analyzed. Magn Reson Med 47:982–989, 2002. © 2002 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.10137

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 255

Metadata

Authors
Yang, Q. X., Wang, J., Zhang, X., Collins, C. M., Smith, M. B., Liu, H., Zhu, X., Vaughan, J. T., Ugurbil, K., & Chen, W.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2002-04-23
Volume
47
Issue
5
Pages
982-989
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2155156416
Cited by
255
References
1
FWCI
6.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Analysis of wave behavior in lossy dielectric samples at high field. https://app.cochat.ai/papers/10.1002/mrm.10137
The paper
Yang, Q. X., Wang, J., Zhang, X., Collins, C. M., Smith, M. B., Liu, H., Zhu, X., Vaughan, J. T., Ugurbil, K., & Chen, W. (2002). Analysis of wave behavior in lossy dielectric samples at high field. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.10137

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.