The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Improved accuracy of human cerebral blood perfusion measurements using arterial spin labeling: Accounting for capillary water permeability
Open accessAbstract
A two‐compartment exchange model for perfusion quantification using arterial spin labeling (ASL) is presented, which corrects for the assumption that the capillary wall has infinite permeability to water. The model incorporates an extravascular and a blood compartment with the permeability surface area product (PS) of the capillary wall characterizing the passage of water between the compartments. The new model predicts that labeled spins spend longer in the blood compartment before exchange. This makes an accurate blood T1 measurement crucial for perfusion quantification; conversely, the tissue T1 measurement is less important and may be unecessary for pulsed ASL experiments. The model gives up to 62% reduction in perfusion estimate for human imaging at 1.5T compared to the single compartment model. For typical human perfusion rates at 1.5T it can be assumed that the venous outflow signal is negligible. This simplifies the solution, introducing only one more parameter than the single compartment model, PS/vbw, where vbw is the fractional blood water volume per unit volume of tissue. The simplified model produces an improved fit to continuous ASL data collected at varying delay time. The fitting yields reasonable values for perfusion and PS/vbw. Magn Reson Med 48:27–41, 2002. © 2002 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Cited by
Yankeelov, T., & Gore, J. (2007) · Current Medical Imaging Reviews · doi:10.2174/157340507780619179 · Cited by 398
Neurogliovascular dysfunction in a model of repeated traumatic brain injury
Adams, C., Bazzigaluppi, P., Beckett, T. L., Bishay, J., Weisspapir, I., Dorr, A., Mester, J. R., Steinman, J., Hirschler, L., Warnking, J. M., et al. (2018) · Theranostics · doi:10.7150/thno.24747 · Cited by 42
Metadata
- Authors
- Parkes, L. M., & Tofts, P. S.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2002-06-27
- Volume
- 48
- Issue
- 1
- Pages
- 27-41
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2129997851
- Cited by
- 202
- References
- 1
- FWCI
- 7.20
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improved accuracy of human cerebral blood perfusion measurements using arterial spin labeling: Accounting for capillary water permeability. https://app.cochat.ai/papers/10.1002/mrm.10180
- The paper
- Parkes, L. M., & Tofts, P. S. (2002). Improved accuracy of human cerebral blood perfusion measurements using arterial spin labeling: Accounting for capillary water permeability. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.10180
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.