Improved accuracy of human cerebral blood perfusion measurements using arterial spin labeling: Accounting for capillary water permeability

Open access
Parkes, Laura M., Tofts, Paul S.·2002·Magnetic Resonance in Medicine

Abstract

A two‐compartment exchange model for perfusion quantification using arterial spin labeling (ASL) is presented, which corrects for the assumption that the capillary wall has infinite permeability to water. The model incorporates an extravascular and a blood compartment with the permeability surface area product (PS) of the capillary wall characterizing the passage of water between the compartments. The new model predicts that labeled spins spend longer in the blood compartment before exchange. This makes an accurate blood T1 measurement crucial for perfusion quantification; conversely, the tissue T1 measurement is less important and may be unecessary for pulsed ASL experiments. The model gives up to 62% reduction in perfusion estimate for human imaging at 1.5T compared to the single compartment model. For typical human perfusion rates at 1.5T it can be assumed that the venous outflow signal is negligible. This simplifies the solution, introducing only one more parameter than the single compartment model, PS/vbw, where vbw is the fractional blood water volume per unit volume of tissue. The simplified model produces an improved fit to continuous ASL data collected at varying delay time. The fitting yields reasonable values for perfusion and PS/vbw. Magn Reson Med 48:27–41, 2002. © 2002 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.10180

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 202

Metadata

Authors
Parkes, L. M., & Tofts, P. S.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2002-06-27
Volume
48
Issue
1
Pages
27-41
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2129997851
Cited by
202
References
1
FWCI
7.20
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Improved accuracy of human cerebral blood perfusion measurements using arterial spin labeling: Accounting for capillary water permeability. https://app.cochat.ai/papers/10.1002/mrm.10180
The paper
Parkes, L. M., & Tofts, P. S. (2002). Improved accuracy of human cerebral blood perfusion measurements using arterial spin labeling: Accounting for capillary water permeability. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.10180

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.