Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 173

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Analysis and generalized correction of the effect of spatial gradient field distortions in diffusion‐weighted imaging

Bammer, R., Markl, M., Barnett, A., Acar, B., Alley, M.T., Pelc, N.J., Glover, G.H., Moseley, M.E.·2003·Magnetic Resonance in Medicine

Abstract

Nonuniformities of magnetic field gradients can cause serious artifacts in diffusion imaging. While it is well known that nonlinearities of the imaging gradients lead to image warping, those imperfections can also cause spatially dependent errors in the direction and magnitude of the diffusion encoding. This study shows that the potential errors in diffusion imaging are considerable. Further, we show that retrospective corrections can be applied to reduce these errors. A general mathematical framework was formulated to characterize the contribution of gradient nonuniformities to diffusion experiments. The gradient field was approximated using spherical harmonic expansion, and this approximation was employed (after geometric distortions were eliminated) to predict and correct the errors in diffusion encoding. Before the corrections were made, the experiments clearly revealed marked deviations of the calculated diffusivity for fields of view (FOVs) generally used in diffusion experiments. These deviations were most significant farther away from the magnet's isocenter. For an FOV of 25 cm, the resultant errors in absolute diffusivity ranged from approximately –10% to +20%. Within the same FOV, the diffusion‐encoding direction and the orientation of the calculated eigenvectors can be significantly altered if the perturbations by the gradient nonuniformities are not considered. With the proposed correction scheme, most of the errors introduced by gradient nonuniformities can be removed. Magn Reson Med 50:560–569, 2003. © 2003 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.10545

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 173

Metadata

Authors
Bammer, R., Markl, M., Barnett, A., Acar, B., Alley, M. T., Pelc, N. J., Glover, G. H., & Moseley, M. E.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2003-08-20
Volume
50
Issue
3
Pages
560-569
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2129460897
Cited by
173
References
1
FWCI
1.81
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Analysis and generalized correction of the effect of spatial gradient field distortions in diffusion‐weighted imaging. https://app.cochat.ai/papers/10.1002/mrm.10545
The paper
Bammer, R., Markl, M., Barnett, A., Acar, B., Alley, M. T., Pelc, N. J., Glover, G. H., & Moseley, M. E. (2003). Analysis and generalized correction of the effect of spatial gradient field distortions in diffusion‐weighted imaging. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.10545

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.