Eddy current correction in diffusion‐weighted imaging using pairs of images acquired with opposite diffusion gradient polarity
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In echo‐planar‐based diffusion‐weighted imaging (DWI) and diffusion tensor imaging (DTI), the evaluation of diffusion parameters such as apparent diffusion coefficients and anisotropy indices is affected by image distortions that arise from residual eddy currents produced by the diffusion‐sensitizing gradients. Correction methods that coregister diffusion‐weighted and non‐diffusion‐weighted images suffer from the different contrast properties inherent in these image types. Here, a postprocessing correction scheme is introduced that makes use of the inverse characteristics of distortions generated by gradients with reversed polarity. In this approach, only diffusion‐weighted images with identical contrast are included for correction. That is, non‐diffusion‐weighted images are not needed as a reference for registration. Furthermore, the acquisition of an additional dataset with moderate diffusion‐weighting as suggested by Haselgrove and Moore (Magn Reson Med 1996;36:960–964) is not required. With phantom data it is shown that the theoretically expected symmetry of distortions is preserved in the images to a very high degree, demonstrating the practicality of the new method. Results from human brain images are also presented. Magn Reson Med 51:188–193, 2004. © 2003 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High angular resolution diffusion imaging reveals intravoxel white matter fiber heterogeneity
Tuch, D. S., Reese, T. G., Wiegell, M. R., Makris, N., Belliveau, J. W., & Wedeen, V. J. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10268 · Cited by 1,548 · cited 1×
“While computational methods based on MR diffusion imaging, such as fiber tracking algorithms (1,2) or the mathematical modeling of high angular resolved diffusion data (3,4), become more and more sophisticated, attention must be paid to the reliability of the input data.”
Method
Cited by
Andersson, J. L. R., & Sotiropoulos, S. N. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.10.019 · Cited by 3,500
Diffusion tensor imaging and beyond
Tournier, J., Mori, S., & Leemans, A. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22924 · Cited by 921
The Human Connectome Project and beyond: Initial applications of 300mT/m gradients
McNab, J. A., Edlow, B. L., Witzel, T., Huang, S. Y., Bhat, H., Heberlein, K., Feiweier, T., Liu, K., Keil, B., Cohen-Adad, J., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.074 · Cited by 359
Improving diffusion MRI using simultaneous multi-slice echo planar imaging
Setsompop, K., Cohen-Adad, J., Gagoski, B. A., Raij, T., Yendiki, A., Keil, B., Wedeen, V. J., & Wald, L. L. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.033 · Cited by 355
Zahr, N. M., Rohlfing, T., Pfefferbaum, A., & Sullivan, E. V. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.09.046 · Cited by 282
Metadata
- Authors
- Bodammer, N., Kaufmann, J., Kanowski, M., & Tempelmann, C.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2003-12-29
- Volume
- 51
- Issue
- 1
- Pages
- 188-193
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2069522536
- Cited by
- 149
- References
- 1
- FWCI
- 3.36
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.