The DOI matches its Crossref record.
FAIR true‐FISP perfusion imaging of the kidneys
Abstract
Most arterial spin labeling (ASL) techniques apply echoplanar imaging (EPI) because this strategy provides relatively high SNR in short measuring times. Unfortunately, those techniques are very susceptible to static magnetic field inhomogeneities and perfusion signals from organs with fast transverse relaxation might decrease due to the exchange of water molecules in capillaries and organ tissue combined with relatively long echo times of EPI sequences. To overcome these problems a novel imaging technique, FAIR True‐FISP, was developed. It combines a FAIR (flow‐sensitive alternating inversion recovery) perfusion preparation and a true fast imaging with steady precession (True‐FISP) data acquisition strategy. True‐FISP was chosen since this sequence type does not show the mentioned disadvantages of EPI, but provides a similar SNR per measuring time. An important problem of this approach is that True‐FISP sequences usually work in a steady state which is independent of a previous preparation of magnetization. For this reason a sequence structure had to be developed which keeps the advantages of True‐FISP and makes the signal intensity sensitive to the FAIR preparation. Breathhold and nonbreathhold examinations of kidneys are presented and possible strategies to quantitative flow measurements are reported. It is shown that correction of spatially inhomogeneous receiver coil characteristics is easily feasible and leads to clinically valuable perfusion examinations of kidneys without application of potentially nephrotoxic contrast media. Magn Reson Med 51:353–361, 2004. © 2004 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Chowdhury, A. H., Cox, E. F., Francis, S. T., & Lobo, D. N. (2012) · Annals of Surgery · doi:10.1097/sla.0b013e318256be72 · Cited by 764
Whole-body MRI at high field: technical limits and clinical potential
Schick, F. (2005) · European Radiology · doi:10.1007/s00330-005-2678-0 · Cited by 314
Self-citation
Metadata
- Authors
- Martirosian, P., Klose, U., Mader, I., & Schick, F.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2004-01-26
- Volume
- 51
- Issue
- 2
- Pages
- 353-361
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1978856658
- Cited by
- 193
- References
- 0
- FWCI
- 5.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.