The DOI matches its Crossref record.
High‐resolution blood flow velocity measurements in the human finger
Open accessAbstract
MR phase contrast blood flow velocity measurements in the human index finger were performed with triggered, nontriggered, and cine acquisition schemes. A strong (Gmax = 200 mT/m), small bore (inner diameter 12 cm) gradient system inserted in a whole body 3 Tesla MR scanner allowed high‐resolution imaging at short echo times, which decreases partial volume effects and flow artifacts. Arterial blood flow velocities ranging from 4.9–19 cm/sec were measured, while venous blood flow was significantly slower at 1.5–7.1 cm/sec. Taking into account the corresponding vessel diameters ranging from 800 μm to 1.8 mm, blood flow rates of 3.0–26 ml/min in arteries and 1.2–4.8 ml/min in veins are obtained. The results were compared to ultrasound measurements, resulting in comparable blood flow velocities in the same subjects. Magn Reson Med 45:716–719, 2001. © 2001 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Chen, S., Zhong, Y., Fan, W., Xiang, J., Wang, G., Zhou, Q., Wang, J., Geng, Y., Sun, R., Zhang, Z., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00701-4 · Cited by 325
Whole-body MRI at high field: technical limits and clinical potential
Schick, F. (2005) · European Radiology · doi:10.1007/s00330-005-2678-0 · Cited by 314
Lekkala, V. K. R., Kang, S.-Y., Liu, J., Shrestha, S., Acharya, P., Joshi, P., Zolfaghar, M., Lee, M., Vanga, M. G., Jamdagneya, P., et al. (2024) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.4c00179 · Cited by 25
Metadata
- Authors
- Klarhöfer, M., Csapo, B., Balassy, C., Szeles, J. C., & Moser, E.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2001-03-27
- Volume
- 45
- Issue
- 4
- Pages
- 716-719
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2143437405
- Cited by
- 168
- References
- 0
- FWCI
- 0.56
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.