Cited by 389Advanced Neuroimaging Techniques and ApplicationsAdvanced MRI Techniques and ApplicationsNMR spectroscopy and applications

Anisotropy in high angular resolution diffusion-weighted MRI

Open access
Frank, Lawrence R.·2001·Magnetic Resonance in Medicine

Abstract

The diffusion in voxels with multidirectional fibers can be quite complicated and not necessarily well characterized by the standard diffusion tensor model. High angular resolution diffusion‐weighted acquisitions have recently been proposed as a method to investigate such voxels, but the reconstruction methods proposed require sophisticated estimation schemes. We present here a simple algorithm for the identification of diffusion anisotropy based upon the variance of the estimated apparent diffusion coefficient (ADC) as a function of measurement direction. The rationale for this method is discussed, and results in normal human subjects acquired with a novel diffusion‐weighted stimulated‐echo spiral acquisition are presented which distinguish areas of anisotropy that are not apparent in the relative anisotropy maps derived from the standard diffusion tensor model. Magn Reson Med 45:935–939, 2001. Published 2001 Wiley‐Liss, Inc.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1125

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • HARDI acquires diffusion-weighted data along many more directions than the minimum six required for tensor estimation.

    “To mitigate the single-tensor crossing-fiber limitation, high-angular-resolution diffusion imaging (HARDI) acquires diffusion-weighted data along many more directions than the minimum six required for tensor estimation (Frank, 2002).”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 26 · Cited by 389

Research works printed but not linked: 25

  1. Carr HY, Purcell EM. Effects of diffusion on free precession in nuclear magnetic resonance experiments. Phys Rev 1954;94:630 -638.
  2. Hahn EL. Detection of sea-water motion by nuclear precession. J Geo- phys Res 1960;65:776.
  3. Cooper RL, Chang DB, Young AC, Martin CJ, Ancker-Johnson B. Re- stricted diffusion in biophysical systems. Biophys J 1974;14:161.
  4. Tanner JE. Transient diffusion in system partitioned by permeable barriers. Application to NMR measurements with a pulsed field gradi- ent. J Chem Phys 1978;69:1748 -1754.
  5. Cotts RM, Hoch MJR, Sun T, Marker JT. Pulsed field gradient stimu- lated echo methods for improved NMR diffusion measurements in heterogeneous systems. J Magn Reson 1989;83:252-266.
  6. Basser PJ, Mattiello J, Le Bihan D. Estimation of the effective self- diffusion tensor from the NMR spin echo. J Magn Reson 1994;103:247- 254.
  7. Basser PJ, Mattiello J, Le Bihan D. MR diffusion tensor spectroscopy and imaging. Biophys J 1994;66:259 -267.
  8. Chenevert TL, Brunberg JA, Pipe JG. Anisotropic diffusion in human white matter: demonstration with MR techniques in vivo. Radiology 1990;177:401-405.
  9. Doran M, Hajnal JV, Van Bruggen N, King MD, Young IR, Bydder G. Normal and abnormal human white matter tracts shown by MR imaging using directional diffusion weighted sequences. J Comput Assist To- mogr 1990;14:865-873.
  10. Mori S, Crain BJ, Chacko VP, van Zijl PC. Three-dimensional tracking of axonal projections in the brain by magnetic resonance imaging. Ann Neurol 1999;45:265-169.
  11. Conturo TE, Lori NF, Cull TS, Akbudak E, Snyder AZ, Shimony JS, McKinstry RC, Burton H, Raichle ME. Tracking neuronal fiber path- ways in the living human brain. Proc Natl Acad Sci USA 1999;96: 10422-10427.
  12. Basser P, Pajevic S, Pierpaoli C, Duda J, Aldroubi A. In vivo fiber tractography in human grain using diffusion tensor MRI (DT MRI) data. Magn Reson Med 2000;44:625-632
  13. Basser PJ, Pierpaoli C. A simplified method to measure the diffusion tensor from seven MR images. Magn Reson Med 1998;39:928 -934.
  14. Pierpaoli C, Basser PJ. Toward a quantitative assessment of diffusion anisotropy. Magn Reson Med 1996;36:893-906.
  15. Tuch DS, Weisskoff RM, Belliveau JW, Wedeen VJ. High angular reso- lution diffusion imaging of the human brain. In: Proceedings of the 7th Annual Meeting of ISMRM, Philadelphia, 1999. p 321.
  16. Wedeen VJ, Reese TG, Tuch DS, Weigel MR, Dou J-G, Weiskoff RM, Chesler D. Mapping fiber orientation spectra in cerebral white matter with Fourier transform diffusion MRI. In: Proceedings of the 8th An- nual Meeting of ISMRM, Denver, 2000. p 82.
  17. Cory DG, Garroway AN. Measurement of translational displacement probabilities by NMR: an indicator of compartmentation. Magn Reson Med 1990;14:435.
  18. Hsu EW, Mori S. Analytical expressions for the NMR apparent diffu- sion coefficients in an anisotropic system and a simplified method for determining fiber orientation. Magn Reson Med 1995;34:194 -200.
  19. Glover GH. Simple analytic spiral k-space algorithm. Magn Reson Med 1999;42:412-415.
  20. Meyer CH, Hu BS, Nishimura DG, Macovski A. Fast spiral coronary artery imaging. Magn Reson Med 1992;28:202-213.
  21. Tanner JE. Use of the stimulated echo in NMR diffusion studies. J Chem Phys 1970;52:2523-2526.
  22. Merboldt K-D, Hanicke W, Frahm J. Self-diffusion NMR imaging using stimulated echoes. J Magn Reson 1995;64:479 -486.
  23. Morich MA, Lampman DA, Dannels WR, Goldie FTD. Exact temporal eddy current compensation in magnetic resonance imaging systems. IEEE Trans Med Imaging 1988;7:247-254.
  24. Trouard TP, Theilman RJ, Altbach MI, Gmitro AF. High resolution diffusion imaging with DIFRAD-FSE (diffusion-weighted radial acqui- sition of data with fast spin-echo) MRI. Magn Reson Med 1999;42:11- 18.
  25. Basser PJ, Pierpaoli C. Microstructural and physiological features of tissues elucidated by quantitative diffusion tensor MRI. J Magn Reson B 1996;111:209 -219.

Authors
Frank, L. R.
Affiliations
University of California San Diego (US)
Corresponding author
Frank, Lawrence R.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2001-05-23
Volume
45
Issue
6
Pages
935-939
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2086858670
Cited by
389
References
26
Citations by year
2026: 2 · 2025: 7 · 2024: 4 · 2023: 6 · 2022: 9 · 2021: 8 · 2020: 8 · 2019: 9 · 2018: 9 · 2017: 8 · 2016: 11 · 2015: 8 · 2014: 14 · 2013: 26 · 2012: 19
FWCI
13.89
Type
journal article
Language
en
Open access
Locations
  • Magnetic Resonance in Medicine (publishedVersion, public-domain)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced Neuroimaging Techniques and Applications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
  • Physical Sciences › Physics and Astronomy › Nuclear and High Energy Physics › NMR spectroscopy and applications
Keywords
diffusion anisotropy, white matter fiber orientation
MeSH terms
Algorithms, Brain, Diffusion, Humans, Image Enhancement, Image Processing, Computer-Assisted, Magnetic Resonance Imaging, Reference Values, Anisotropy

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review