The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
RARE imaging: A fast imaging method for clinical MR
Abstract
Based on the principles of echo imaging, we presnet a method to acquire sufficient data for a 256 × 256 image in from 2 to 40s. The image contrast is dominated by the transverse relaxation time T2 Sampling all projections for 2D FT image reconstruction in one (or a few) echo trains leads to image artifacts due to the different T2 weighting of the echo. These artifacts cannot be described by a simple smearing out of the image in the phase direction. Proper distribution of the phase‐encoding steps on the echoes can be used to minimize artifacts and even lead to resolution enhancement. In spite of the short data acquisition times, the signal amplitudes of structures with long T2 are nearly the same as those in a conventional 2D FT experiment. Our method, therefore, is an ideal screening technique for lesions with long T2. © 1986 Academic Press, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Modified Spin-Echo Method for Measuring Nuclear Relaxation Times
Meiboom, S., & Gill, D. (1958) · Review of Scientific Instruments · doi:10.1063/1.1716296 · Cited by 6,022
Kumar, A., Welti, D., & Ernst, R. R. (1975) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(75)90224-3 · Cited by 311
REAL-TIME ECHO-PLANAR IMAGING BY NMR
Mansfield, P. (1984) · British Medical Bulletin · doi:10.1093/oxfordjournals.bmb.a071970 · Cited by 136
Cited by
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
Yang, G., Yu, S., Dong, H., Slabaugh, G., Dragotti, P. L., Ye, X., Liu, F., Arridge, S., Keegan, J., Guo, Y., et al. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2785879 · Cited by 1,081
Motion artifacts in MRI: A complex problem with many partial solutions
Zaitsev, M., Maclaren, J., & Herbst, M. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24850 · Cited by 774
Ojemann, J. G., Akbudak, E., Snyder, A. Z., McKinstry, R. C., Raichle, M. E., & Conturo, T. E. (1997) · NeuroImage · doi:10.1006/nimg.1997.0289 · Cited by 694
Snapshot flash mri. applications to t1, t2, and chemical‐shift imaging
Haase, A. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910130109 · Cited by 693
Metadata
- Authors
- Hennig, J., Nauerth, A., & Friedburg, H.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1986-12
- Volume
- 3
- Issue
- 6
- Pages
- 823-833
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2154108863
- Cited by
- 2,081
- References
- 3
- FWCI
- 5.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.