Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 253

The DOI matches its Crossref record.

An analysis of fast imaging sequences with steady‐state transverse magnetization refocusing

Zur, Yuval, Stokar, Saul, Bendel, Peter·1988·Magnetic Resonance in Medicine

Abstract

Recently, several groups have proposed and demonstrated the use of rapid imaging methods, using short pulse repetition times and gradient‐reversal echoes. Here, we analyze the behavior of the magnetization and the resulting image contrasts in such sequences for the case where the pulse repetition time T R is of the order of, or shorter than, the transverse relaxation time T 2, and the transverse magnetization is not destroyed between phase‐encoding cycles. Exact analytical expressions describing the signal evolution between the pulses are derived, taking into account the effects of resonance offsets and flip angles, and examining the influence of constant‐phase or alternate‐phase RF pulse trains. It is shown that for typical imaging sequences two distinct echo signals will develop between pulses, which may have a detrimental effect on image quality if they partially overlap within the sampling window. It is shown that artifact‐free images can be obtained only if the two echo signals overlap precisely, which seems technically close to impossible to achieve, or if they are sufficiently separated in time to allow sampling of only one of the signals. © 1988 Academic Press, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1910060206

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 253

Metadata

Authors
Zur, Y., Stokar, S., & Bendel, P.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
1988-02
Volume
6
Issue
2
Pages
175-193
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2077084400
Cited by
253
References
0
FWCI
7.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An analysis of fast imaging sequences with steady‐state transverse magnetization refocusing. https://app.cochat.ai/papers/10.1002/mrm.1910060206
The paper
Zur, Y., Stokar, S., & Bendel, P. (1988). An analysis of fast imaging sequences with steady‐state transverse magnetization refocusing. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910060206

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.