The DOI matches its Crossref record.
An analysis of fast imaging sequences with steady‐state transverse magnetization refocusing
Abstract
Recently, several groups have proposed and demonstrated the use of rapid imaging methods, using short pulse repetition times and gradient‐reversal echoes. Here, we analyze the behavior of the magnetization and the resulting image contrasts in such sequences for the case where the pulse repetition time T R is of the order of, or shorter than, the transverse relaxation time T 2, and the transverse magnetization is not destroyed between phase‐encoding cycles. Exact analytical expressions describing the signal evolution between the pulses are derived, taking into account the effects of resonance offsets and flip angles, and examining the influence of constant‐phase or alternate‐phase RF pulse trains. It is shown that for typical imaging sequences two distinct echo signals will develop between pulses, which may have a detrimental effect on image quality if they partially overlap within the sampling window. It is shown that artifact‐free images can be obtained only if the two echo signals overlap precisely, which seems technically close to impossible to achieve, or if they are sufficiently separated in time to allow sampling of only one of the signals. © 1988 Academic Press, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Deoni, S. C. L., Peters, T. M., & Rutt, B. K. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20314 · Cited by 478
Samiotaki, G., Karakatsani, M. E., Buch, A., Papadopoulos, S., Wu, S. Y., Jambawalikar, S., & Konofagou, E. E. (2017) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2016.11.023 · Cited by 35
Metadata
- Authors
- Zur, Y., Stokar, S., & Bendel, P.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1988-02
- Volume
- 6
- Issue
- 2
- Pages
- 175-193
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2077084400
- Cited by
- 253
- References
- 0
- FWCI
- 7.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An analysis of fast imaging sequences with steady‐state transverse magnetization refocusing. https://app.cochat.ai/papers/10.1002/mrm.1910060206
- The paper
- Zur, Y., Stokar, S., & Bendel, P. (1988). An analysis of fast imaging sequences with steady‐state transverse magnetization refocusing. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910060206
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.