CoChat

Proton‐decoupled, overhauser‐enhanced, spatially localized carbon‐13 spectroscopy in humans

Bottomley, Paul A., Hardy, Christopher J., Roemer, Peter B., Mueller, Otward M. · 1989 · Magnetic Resonance in Medicine
Cited by 98

The DOI matches its Crossref record.

Abstract

Spatially localized, natural abundance, carbon (13 C) NMR spectroscopy has been combined with proton (1 H) decoupling and nuclear Overhauser enhancement to improve I3 C sensitivity up to five‐fold in the human leg, liver, and heart. Broadband‐decoupled 13 C spectra were acquired in 1 s to 17 min with a conventional 1.5‐T imaging/ spectroscopy system, an auxiliary 1 H decoupler, an air‐cooled dual‐coil coplanar surface probe, and both depth‐resolved surface coil spectroscopy (DRESS) and one‐dimensional phase‐encoding gradient NMR pulse sequences. The surface coil probe comprised circular and figure‐eight‐shaped coils to eliminate problems with mutual coupling of coils at high decoupling power levels applied during I3 C reception. Peak decoupler RF power deposition in tissue was computed numerically from electromagnetic theory assuming a semi‐infinite plane of uniform biological conductor. Peak values at the surface were calculated at 4 to 6 W/kg in any gram of tissue for each watt of decoupler power input excluding all coil and cable losses, warning of potential local RF heating problems in these and related experiments. The average power deposition was about 9 mW/kg per watt input, which should present no systemic hazard. At 3 W input, human 13 C spectra were decoupled to a depth of about 5 cm while some Overhauser enhancement was sustained up to about 3 cm depth, without ill effect. The observation of glycogen in localized natural abundance 13 C spectra of heart and muscle suggests that metabolites in the citric acid cycle should be observable noninvasively using 13 C‐labeled substrates. © 1989 Academic Press, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1910120307

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 98

Metadata

Authors
Bottomley, P. A., Hardy, C. J., Roemer, P. B., & Mueller, O. M.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
1989-12
Volume
12
Issue
3
Pages
348-363
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2045316236
Cited by
98
References
0
FWCI
6.70
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Proton‐decoupled, overhauser‐enhanced, spatially localized carbon‐13 spectroscopy in humans. https://app.cochat.ai/papers/10.1002/mrm.1910120307
The paper
Bottomley, P. A., Hardy, C. J., Roemer, P. B., & Mueller, O. M. (1989). Proton‐decoupled, overhauser‐enhanced, spatially localized carbon‐13 spectroscopy in humans. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910120307

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.