CoChat

Transmural high energy phosphate distribution and response to alterations in workload in the normal canine myocardium as studied with spatially localized 31P NMR spectroscopy

Robitaille, P‐M., Merkle, H., Lew, B., Path, G., Hendrich, K., Lindstrom, P., From, A. H. L., Garwood, M., Bache, R. J., Uǧurbil, K. · 1990 · Magnetic Resonance in Medicine
Cited by 85

The DOI matches its Crossref record.

Abstract

Spatially localized phosphorus‐31 nuclear magnetic resonance (31 P NMR) spectroscopy has been applied to the study of the normal canine myocardium to measure the relative content of high energy phosphates across the left ventricular wall. Transmural NMR data were acquired in five voxels spanning the wall of the left ventricle using the FLAX‐ISIS technique. The validity of the FLAX‐ISIS approach in acquiring localized spectra for transmural studies and in providing quantitative information from the localized spectra was examined rigorously by studies involving phantoms, intact rats, and the canine myocardium in vivo. The results indicated that (1) this technique yields spatially resolved spectra with partial overlap between adjacent voxels and virtually no overlap between every other voxel; (2) in the canine heart, signals from subepicardium, midwall, and sub‐endocardium can be detected separately without cross contamination; and (3) relative metabolite contents within a voxel and among voxels can be quantitated. Transmural 31 P NMR spectra were acquired with cardiac gating on 29 separate animals either at early systole or late diastole, and at three different workloads with the heart rate peak systolic pressure product (RPP) increasing from 6000 mmHg/min to 35,000 mmHg/min. The data revealed that in the normal canine myocardium, the creatine phosphate (CP) content and the CP/ATP ratio was significantly lower in the subendocardium than in the subepicardium. ATP levels were transmurally constant. Both the CP content and the CP/ATP ratio measured for each voxel remained unaltered in relation to either the phase of the cardiac cycle or ∼ fourfold increase in workload. Free ADP levels calculated for each voxel showed that ADP was relatively higher in the subendocardium than the subepicardium, and in all transmural layers was higher than its apparent Km for oxidative phosphorylation. In this domain changes in ADP content with workload and MVO 2 are not expected and were not observed. © 1990 Academic Press, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1910160110

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 85

Metadata

Authors
Robitaille, P., Merkle, H., Lew, B., Path, G., Hendrich, K., Lindstrom, P., From, A. H. L., Garwood, M., Bache, R. J., & Uǧurbil, K.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
1990-10
Volume
16
Issue
1
Pages
91-116
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2003598390
Cited by
85
References
0
FWCI
8.99
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Transmural high energy phosphate distribution and response to alterations in workload in the normal canine myocardium as studied with spatially localized 31P NMR spectroscopy. https://app.cochat.ai/papers/10.1002/mrm.1910160110
The paper
Robitaille, P., Merkle, H., Lew, B., Path, G., Hendrich, K., Lindstrom, P., From, A. H. L., Garwood, M., Bache, R. J., & Uǧurbil, K. (1990). Transmural high energy phosphate distribution and response to alterations in workload in the normal canine myocardium as studied with spatially localized 31P NMR spectroscopy. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910160110

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.