Measurements of pertinent concentrations of oxygen in vivo
The DOI matches its Crossref record.
Abstract
A new method able to measure the concentration of oxygen in complex biological systems, including in vivo, has been developed using low‐frequency EPR and newly characterized free radicals that are very sensitive to the concentration of oxygen. The free radicals (fusinite and lithium phthalocyanine) are very stable in tissues (for at least 150 days), apparently nontoxic, and can reflect oxygen concentrations that are less than the K m of cytochrome oxidase (0.1 μ M or lower). Their biological stability is indicated by the fact that repeated measurements with fusinite of the concentration of oxygen in skeletal muscle have been made in the same animal for more than 150 days without any change in sensitivity or signs of toxicity. © 1991 Academic Press, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Liu, K. J., Gast, P., Moussavi, M., Norby, S. W., Vahidi, N., Walczak, T., Wu, M., & Swartz, H. M. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.12.5438 · Cited by 318
Self-citationStone, H. B., Brown, J. M., Phillips, T. L., & Sutherland, R. M. (1993) · Radiation Research · doi:10.2307/3578556 · Cited by 303
The measurement of oxygen in vivo using EPR techniques
Swartz, H. M., & Clarkson, R. B. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/7/017 · Cited by 218
Self-citationRadiofrequency microcoils in magnetic resonance
G. Webb, A. (1997) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/s0079-6565(97)00004-6 · Cited by 216
Torres Filho, I. P., Leunig, M., Yuan, F., Intaglietta, M., & Jain, R. K. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.6.2081 · Cited by 189
Metadata
- Authors
- Swartz, H. M., Boyer, S., Gast, P., Glockner, J. F., Hu, H., Liu, K. J., Moussavi, M., Norby, S. W., Vahidi, N., Walczak, T., Wu, M., & Clarkson, R. B.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1991-08
- Volume
- 20
- Issue
- 2
- Pages
- 333-339
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2119304399
- Cited by
- 90
- References
- 0
- FWCI
- 8.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurements of pertinent concentrations of oxygen in vivo. https://app.cochat.ai/papers/10.1002/mrm.1910200217
- The paper
- Swartz, H. M., Boyer, S., Gast, P., Glockner, J. F., Hu, H., Liu, K. J., Moussavi, M., Norby, S. W., Vahidi, N., Walczak, T., Wu, M., & Clarkson, R. B. (1991). Measurements of pertinent concentrations of oxygen in vivo. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910200217
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.