The DOI matches its Crossref record.
Projection Reconstruction Techniques for Reduction of Motion Effects in MRI
Abstract
Projection reconstruction (PR) techniques are shown to have intrinsic advantages over spin‐warp (2DFT) methods with respect to diminished artifacts from respiratory motion. The benefits result from (1) portrayal of artifacts as radial streaks, with the amplitude smallest near the moving elements; (2) streak deployment perpendicular to the direction of motion of moving elements and often residing outside the anatomic boundaries of the subject; (3) inherent signal averaging of low spatial frequencies from oversampling of central k‐space data. In addition, respiratory‐ordered view angle (ROVA) acquisition is found to diminish residual streaking significantly by reducing interview inconsistencies. Comparisons of 2DFT and PR acquisitions are made with and without ROVA. Reconstructions from magnitude‐only projections are found to have increased streaks from motion‐induced phase shifts.© 1992 Academic Press,Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Markl, M., Frydrychowicz, A., Kozerke, S., Hope, M., & Wieben, O. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23632 · Cited by 788
Zaitsev, M., Dold, C., Sakas, G., Hennig, J., & Speck, O. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.01.039 · Cited by 391
Giger, M. L., Chan, H., & Boone, J. (2008) · Medical Physics · doi:10.1118/1.3013555 · Cited by 311
Metadata
- Authors
- Glover, G. H., & Pauly, J. M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1992-12
- Volume
- 28
- Issue
- 2
- Pages
- 275-289
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2091719438
- Cited by
- 563
- References
- 0
- FWCI
- 4.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Projection Reconstruction Techniques for Reduction of Motion Effects in MRI. https://app.cochat.ai/papers/10.1002/mrm.1910280209
- The paper
- Glover, G. H., & Pauly, J. M. (1992). Projection Reconstruction Techniques for Reduction of Motion Effects in MRI. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910280209
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.