Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 172

The DOI matches its Crossref record.

Measurement of capillary permeability to macromolecules by dynamic magnetic resonance imaging: A quantitative noninvasive technique

Shames, David M., Kuwatsuru, Ryohei, Vexler, Vladimir, Mühler, Andreas, Brasch, Robert C.·1993·Magnetic Resonance in Medicine

Abstract

A simple, linear kinetic model has been developed for the noninvasive assessment of capillary permeability to macromolecules in the rat by dynamic magnetic resonance imaging using albumin‐Gd‐DTPA. Data required by the model are signal intensity responses from a target tissue and a venous structure such as inferior vena cava before and after bolus intravenous injection of albumin‐Gd‐DTPA. Additional requirements include an early temporal resolution of approximately one image/min and a blood sample for hematocrit. The model does not require measurement of albumin‐Gd‐DTPA concentration in either arterial or venous blood. Pilot experiments suggest that this technique is adequate for estimation of the fractional leak rate of macromolecules from plasma to interstitial water as well as tissue plasma volume, the product of which yields a measure of the permeability surface area product of the tissue if the extraction fraction is modest (<0.2). The technique may be generally applicable to the study of abnormal capillary permeability in humans as well as animals.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1910290506

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 172

Metadata

Authors
Shames, D. M., Kuwatsuru, R., Vexler, V., Mühler, A., & Brasch, R. C.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
1993-05
Volume
29
Issue
5
Pages
616-622
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W1992333345
Cited by
172
References
0
FWCI
6.81
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measurement of capillary permeability to macromolecules by dynamic magnetic resonance imaging: A quantitative noninvasive technique. https://app.cochat.ai/papers/10.1002/mrm.1910290506
The paper
Shames, D. M., Kuwatsuru, R., Vexler, V., Mühler, A., & Brasch, R. C. (1993). Measurement of capillary permeability to macromolecules by dynamic magnetic resonance imaging: A quantitative noninvasive technique. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910290506

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.