CoChat

Novel approaches to low‐cost MRI

Macovski, Albert, Conolly, Steven · 1993 · Magnetic Resonance in Medicine
Cited by 140

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

This paper presents a combination of speculative approaches, some related to earlier work and some apparently novel, which show great promise in providing a new class of MRI machines that would be considerably less expensive. This class would have advantages and disadvantages as compared to existing MRI, over and above that of low cost. The disadvantages include the apparent inability to perform classic spectroscopy, and limited flexibility in the area of selective excitation. The advantages include a fundamental immunity to inhoinogenelty and susceptibility problems, the ability to create a wide class of machines that are designed for specific anatomy‐related applications, the ability to design open machines for physician access, and improved capability for high speed imaging. Generic to all of the methods presented are a pulsed polarizing field and an oscillatory readout bias field. The pulsed field initially polarizes the magnetic moments. Sinat it is not on during the readout operation it has negligible homogeneity requirements since changes in the field amplitude will merely shade the image intensity. During readout a relatively low bias field is used. To enable the use of a relatively inhomogeneous bias field, an osciliatory field is used that has a zero average value. This prevents any long‐term buildup of phase errors due to a frequency error associated with inhomogeneity. Thus the average bias frequency will be determined solely by the frequency rather than the amplitude of the bias field. Three methods are described, all including the above features. The first two involve imaging in the laboratory frame, while the third involves imaging in the rotating frame. The second approach requires no RF excitation and the third approach uses RF bias and gradient signals. Some approaches to slice selection are described.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1910300211

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Macovski, A., & Conolly, S.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
1993-08
Volume
30
Issue
2
Pages
221-230
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W1971395377
Cited by
140
References
1
FWCI
2.27
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.