Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 170

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Apparent diffusion coefficient mapping of experimental focal cerebral ischemia using diffusion‐weighted echo‐planar imaging

Dardzinski, Bernard J., Sotak, Christopher H., Fisher, Marc, Hasegawa, Yasuhiro, Li, Lirnin, Minematsu, Kazuo · 1993 · Magnetic Resonance in Medicine

Abstract

Diffusion‐weighted, echo‐planar imaging (EPI) was used to map regional changes In the apparent diffusion coefficient (ADC) during experimental focal ischemia in the rat brain following permanent middle cerebral arterial occlusion (MCAO). Sixteen 64 × 64 diffusion‐weighted EPIs were acquired in 32 s with successively increasing amplitudes of the diffusion‐sensitive gradient pulses. A linear least‐squares regression algorithm was used to fit 15 of the 16 two‐dimensional matrices, on a pixel‐by‐pixel basis, to solve for the slope from which the ADC value was calculated. The correlation coefficient of the fit, R 2 was used to filter the final ADC maps, and the ADCs were then scaled appropriately to be displayed in a 256 gray level format. Ranges (bins) of 0.05 × 10−3 mm 2/s were then grouped and color coded to qualify and quantify the evolution of ischemia in the MCA territory. The percentage of area in the ischemic and contralateral hemispheres in seven ADC bins were calculated at 30, 60, and 120 min after MCAO for 10 animals and demonstrated a significant increase in ADC bins below 0.45 × 10−3 mm 2/s and a decrease in bins above 0.50 × 10−3 mm 2/s over the. The postmortem infarct area, as measured by TTC staining, was highly correlated with the portion of the ischemic hemisphere falling below ADC values of 0.55 × 10−3 mm 2/s at 2 h after stroke onset. These studies suggest that focally ischemic brain tissue can be quantitatively subdivided according to ADC values and that ADC values below 0.55 × 10−3 mm 2/s 2 h following ischemia highly predict infarction in a rat permanent occlusion stroke model.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1910300307

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 170

Metadata

Authors
Dardzinski, B. J., Sotak, C. H., Fisher, M., Hasegawa, Y., Li, L., & Minematsu, K.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
1993-09
Volume
30
Issue
3
Pages
318-325
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2030591899
Cited by
170
References
2
FWCI
12.11
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.