The DOI matches its Crossref record.
Mr contrast due to intravascular magnetic susceptibility perturbations
Abstract
A particularly powerful paradigm for functional MR imaging of microvascular hemodynamics incorporates paramagnetic materials that create significant image contrast. These include exogenous (lanthanide chelates) and endogenous (de‐oxygenated hemoglobin) agents for mapping cerebral blood volume and neuronal activity, respectively. Accurate interpretation of these maps requires an understanding of the bio‐physics of susceptibility‐based image contrast. The authors developed a novel Monte Carlo model with which the authors quantified the relationship between microscopic tissue parameters, NMR imaging parameters, and susceptibility contrast in vivo. The authors found vascular permeability to water and the flow of erythrocytes to be relatively unimportant contributors to susceptibility‐induced ΔR2. However, pulse sequence, echo time, and concentration of contrast agent have profound effects on the vessel size dependence of ΔR2. For a model vasculature containing both capillaries and venules, the authors predicted a linear volume fraction dependence for physiological volume changes based on recruitment and dilation, and a concentration dependence that is nonlinear and pulse sequence dependent. Using the model, the authors demonstrated that spin echo functional images have greater microvascular sensitivity than gradient echo images, and that the specifics of the volume fraction and concentration dependence of transverse relaxivity change should allow for robust mapping of relative blood volume. The authors also demonstrated excellent agreement between the predictions of their model and experimental data obtained from the serial injection of superparamagnetic contrast agent in a rat model.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
What we can do and what we cannot do with fMRI
Logothetis, N. K. (2008) · Nature · doi:10.1038/nature06976 · Cited by 3,612
Wise, R. G., Ide, K., Poulin, M. J., & Tracey, I. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.11.025 · Cited by 664
Molecular diffusion, tissue microdynamics and microstructure
Bihan, D. L. (1995) · NMR in Biomedicine · doi:10.1002/nbm.1940080711 · Cited by 497
Uludağ, K., Müller-Bierl, B., & Uğurbil, K. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.05.051 · Cited by 450
Layer-specific variation of iron content in cerebral cortex as a source of MRI contrast
Fukunaga, M., Li, T.-Q., van Gelderen, P., de Zwart, J. A., Shmueli, K., Yao, B., Lee, J., Maric, D., Aronova, M. A., Zhang, G., et al. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0911177107 · Cited by 408
Metadata
- Authors
- Boxerman, J. L., Hamberg, L. M., Rosen, B. R., & Weisskoff, R. M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1995-10
- Volume
- 34
- Issue
- 4
- Pages
- 555-566
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2019540655
- Cited by
- 1,008
- References
- 0
- FWCI
- 22.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mr contrast due to intravascular magnetic susceptibility perturbations. https://app.cochat.ai/papers/10.1002/mrm.1910340412
- The paper
- Boxerman, J. L., Hamberg, L. M., Rosen, B. R., & Weisskoff, R. M. (1995). Mr contrast due to intravascular magnetic susceptibility perturbations. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910340412
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.