Diffusion weighted fMRI at 1.5 T
Abstract
Functional magnetic resonance imaging (fMRI) is capable of detecting task-induced blood oxygenation changes using susceptibility sensitive pulse sequences such as gradient-recalled echo-planar imaging (EPI). The local signal increases seen in the time course are believed to be due to an increase in oxygen delivery that is incommensurate with oxygen demands. To help isolate the sources of functional signal changes, the authors have incorporated various forms of diffusion weighting into EPI pulse sequences to characterize the apparent mobility of the functionally modulated protons. Results suggest that the majority of the functional signal at 1.5 T arises from protons that have apparent diffusion coefficients that are approximately four or five times higher than that of brain tissue. This implies that significant functional signal sources are either protons within the vascular space or protons from the perivascular space that is occupied by cerebrospinal fluid.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Later studies confirmed the validity of the IVIM concept: increases in low-b ADC and IVIM perfusion parameters were observed in activated brain regions, also revealing contributions from different vessel types to the fMRI signal.
“Later studies nevertheless confirmed the validity of the IVIM concept: increases in low-b ADC and IVIM perfusion parameters were observed in activated brain regions, also revealing contributions from different vessel types to the fMRI signal (Song et al., 1996).”
From 40 Years of diffusion MRI in the brain: From history to emerging frontiers (2026) · cites this paper as Song et al., 1996
The citation lists haven’t been fetched yet
References 12 · Cited by 208
- Authors
- Song, A. W., Wong, E. C., Tan, S. G., & Hyde, J. S.
- Affiliations
- Medical College of Wisconsin (US)
- Corresponding author
- Hyde, James S.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1996-02
- Volume
- 35
- Issue
- 2
- Pages
- 155-158
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1988095568
- Cited by
- 208
- References
- 12
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 3 · 2023: 3 · 2022: 3 · 2021: 1 · 2020: 1 · 2019: 1 · 2018: 3 · 2017: 4 · 2016: 2 · 2015: 7 · 2014: 7 · 2013: 6 · 2012: 10
- FWCI
- 12.95
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Magnetic Resonance in Medicine (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r01ca041464-14)
- National Cancer Institute (CA41464)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced Neuroimaging Techniques and Applications
- Life Sciences › Neuroscience › Cognitive Neuroscience › Functional Brain Connectivity Studies
- Keywords
- apparent diffusion coefficient, cerebral blood flow, cerebrospinal fluid, perivascular spaces, 1.5 Tesla
- MeSH terms
- Adult, Diffusion, Female, Humans, Magnetic Resonance Imaging, Male, Motor Cortex, Echo-Planar Imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review