Single‐shot diffusion MRI of human brain on a conventional clinical instrument
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A single‐shot diffusion MRI technique on a standard clinical 1.5T scanner is presented. The method incorporates the following elements: (a) an inversion RF pulse followed by a delay of 1.3 s to null cerebral spinal fluid (CSF) signal, (b) a stimulated echo sequence (TE=56 ms, TM=100 ms) to obtain strong diffusion weighting, (c) a single‐shot gradient‐ and spin‐echo (GRASE) sequence for imaging with a modified k‐space trajectory and Carr‐Purcell Meiboom‐Gill (CPMG)‐phase cycle. The trace of the diffusion coefficient obtained with this approach is in good agreement with values reported for animal brain, and for recent human studies. It is demonstrated that single‐shot diffusion imaging of human brain is feasible on an unmodified standard instrument without high‐gradient slew rate or extreme field homogeneity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moseley, M. E., Cohen, Y., Mintorovitch, J., Chileuitt, L., Shimizu, H., Kucharczyk, J., Wendland, M. F., & Weinstein, P. R. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140218 · Cited by 1,644
Fast magnetic resonance diffusion-weighted imaging of acute human stroke
Warach, S., Chien, D., Li, W., Ronthal, M., & Edelman, R. R. (1992) · Neurology · doi:10.1212/wnl.42.9.1717 · Cited by 881
Cited by
Diffusion-weighted MR Imaging of the Brain
Schaefer, P. W., Grant, P. E., & Gonzalez, R. G. (2000) · Radiology · doi:10.1148/radiology.217.2.r00nv24331 · Cited by 1,052
Twenty‐five pitfalls in the analysis of diffusion MRI data
Jones, D. K., & Cercignani, M. (2010) · NMR in Biomedicine · doi:10.1002/nbm.1543 · Cited by 827
Porter, D. A., & Heidemann, R. M. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22024 · Cited by 593
A simplified method to measure the diffusion tensor from seven MR images
Basser, P. J., & Pierpaoli, C. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390610 · Cited by 583
Magnetic Resonance Imaging of Acute Stroke
Baird, A. E., & Warach, S. (1998) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199806000-00001 · Cited by 545
Tuch, D. S., Salat, D. H., Wisco, J. J., Zaleta, A. K., Hevelone, N. D., & Rosas, H. D. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0407259102 · Cited by 364
State-of-the-Art Imaging of Acute Stroke
Srinivasan, A., Goyal, M., Azri, F. A., & Lum, C. (2006) · RadioGraphics · doi:10.1148/rg.26si065501 · Cited by 335
Metadata
- Authors
- Liu, G., Van Gelderen, P., Duyn, J., & Moonen, C. T. W.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1996-05
- Volume
- 35
- Issue
- 5
- Pages
- 671-677
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2089758690
- Cited by
- 46
- References
- 2
- FWCI
- 7.20
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.