Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 199

The DOI matches its Crossref record.

Frequency offset corrected inversion (FOCI) pulses for use in localized spectroscopy

Ordidge, Roger J., Wylezinska, Marzena, Hugg, James W., Butterworth, Edward, Franconi, Florence · 1996 · Magnetic Resonance in Medicine

Abstract

Gradient localized spectroscopy techniques suffer from a well documented spatial localization error caused by the difference in chemical shifts between resonances. This results in the acquisition of spectra from partially overlapping spatial regions of the sample, with each resonance representing a different region. The image‐selected in vivo spectroscopy technique uses hyperbolic secant inversion pulses, where the main limitation in reducing this error is in the RF power available for application of the selective RF pulse. This spatial localization error may be dramatically reduced by increasing, and temporally shaping, the gradient pulse during slice‐selective spin inversion. The performance of these RF pulses have been experimentally verified.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1910360410

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 199

Metadata

Authors
Ordidge, R. J., Wylezinska, M., Hugg, J. W., Butterworth, E., & Franconi, F.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
1996-10
Volume
36
Issue
4
Pages
562-566
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2038464762
Cited by
199
References
0
FWCI
3.60
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Frequency offset corrected inversion (FOCI) pulses for use in localized spectroscopy. https://app.cochat.ai/papers/10.1002/mrm.1910360410
The paper
Ordidge, R. J., Wylezinska, M., Hugg, J. W., Butterworth, E., & Franconi, F. (1996). Frequency offset corrected inversion (FOCI) pulses for use in localized spectroscopy. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910360410

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.