Spatially filtering functional magnetic resonance imaging data
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
When constructing MR images from acquired spatial frequency data, it can be beneficial to apply a low‐pass filter to remove high frequency noise from the resulting images. This amounts to attenuating high spatial frequency fluctuations that can affect detected MR signal. A study is presented of spatially filtering MR data and possible ramifications on detecting regionally specific activation signal. It is shown that absolute activation levels are strongly dependent on the parameters of the filter used in image construction and that significance of an activation signal can be enhanced through appropriate filter selection. A comparison is made between spatially filtering MR image data and applying a Gaussian convolution kernel to statistical parametric maps.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Forman, S. D., Cohen, J. D., Fitzgerald, M., Eddy, W. F., Mintun, M. A., & Noll, D. C. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330508 · Cited by 3,202
Cited by
Functional connectivity in single and multislice echoplanar imaging using resting-state fluctuations
Lowe, M. J., Mock, B. J., & Sorenson, J. A. (1998) · NeuroImage · doi:10.1006/nimg.1997.0315 · Cited by 1,394
Self-citationAnand, A., Li, Y., Wang, Y., Wu, J., Gao, S., Bukhari, L., Mathews, V. P., Kalnin, A., & Lowe, M. J. (2005) · Biological Psychiatry · doi:10.1016/j.biopsych.2005.02.021 · Cited by 787
Self-citationThe neural substrates of affective processing in depressed patients treated with venlafaxine
Davidson, R. J., Irwin, W., Anderle, M. J., & Kalin, N. H. (2003) · American Journal of Psychiatry · doi:10.1176/appi.ajp.160.1.64 · Cited by 487
Normal fMRI Brain Activation Patterns in Children Performing a Verb Generation Task
Holland, S. K., Plante, E., Weber Byars, A., Strawsburg, R. H., Schmithorst, V. J., & Ball, W. S. (2001) · NeuroImage · doi:10.1006/nimg.2001.0875 · Cited by 424
fMRI study of language lateralization in children and adults
Szaflarski, J. P., Holland, S. K., Schmithorst, V. J., & Byars, A. W. (2006) · Human Brain Mapping · doi:10.1002/hbm.20177 · Cited by 390
Metadata
- Authors
- Lowe, M. J., & Sorenson, J. A.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1997-05
- Volume
- 37
- Issue
- 5
- Pages
- 723-729
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2111144178
- Cited by
- 135
- References
- 2
- FWCI
- 6.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Spatially filtering functional magnetic resonance imaging data. https://app.cochat.ai/papers/10.1002/mrm.1910370514
- The paper
- Lowe, M. J., & Sorenson, J. A. (1997). Spatially filtering functional magnetic resonance imaging data. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910370514
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.