Ghost artifact reduction for echo planar imaging using image phase correction
The DOI matches its Crossref record.
Abstract
An algorithm is described for reducing ghost artifacts in echo planar imaging (EPI) using phase corrections derived from images reconstructed using only even or odd k‐space lines. The N/2 ghost, that arises principally from time‐reversal of alternate k‐space lines, was significantly reduced by this algorithm without the need for a calibration scan. In images obtained in eight subjects undergoing EPI for auditory functional MRI (fMRI) experiments, N/2 ghost intensity was reduced from 10.3% – 2.1% (range: 7.9–14.1%) to 4.5% ± 0.2% (range: 4.1–4.9%) of parent image intensity, corresponding to a percent reduction in ghost intensity of 54% ± 9% (range: 43–65%), and the algorithm restored this intensity to the parent image. It provided a significant improvement in image appearance, and increased the correlation coefficients related to neural activation in functional MRI studies. The algorithm provided reduction of artifacts from all polynomial orders of spatial phase errors in both spatial directions. The algorithm did not eliminate N/2 ghost intensity contributed by field inhomogeneities, susceptibility, or chemical shift.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The neural mechanisms of top-down attentional control
Hopfinger, J. B., Buonocore, M. H., & Mangun, G. R. (2000) · Nature Neuroscience · doi:10.1038/72999 · Cited by 1,876
“Fourier image reconstruction included N/2 ghost correction using image phase correctio”
MethodSelf-citationPosterior cingulate cortex activation by emotional words: fMRI evidence from a valence decision task
Maddock, R. J., Garrett, A. S., & Buonocore, M. H. (2003) · Human Brain Mapping · doi:10.1002/hbm.10075 · Cited by 695
Self-citationRemembering familiar people: the posterior cingulate cortex and autobiographical memory retrieval
Maddock, R. J., Garrett, A. S., & Buonocore, M. H. (2001) · Neuroscience · doi:10.1016/s0306-4522(01)00108-7 · Cited by 551
Self-citationMadore, B., Glover, G. H., & Pelc, N. J. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<813::aid-mrm1>3.0.co;2-s · Cited by 433
Separating subjective emotion from the perception of emotion-inducing stimuli: An fMRI study
Garrett, A. S., & Maddock, R. J. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.05.024 · Cited by 82
“Images were reconstructed using a Fourier transform-based algorithm with removal of N/2 ghost artifacts (Buonocore and Gao, 1997).”
MethodIanuş, A., Carvalho, J., Fernandes, F. F., Cruz, R., Chavarrias, C., Palombo, M., & Shemesh, N. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.119135 · Cited by 40
Identifying global anatomical differences: Deformation-based morphometry
(1998) · doi:10.1002/(sici)1097-0193(1998)6:5/6
Metadata
- Authors
- Buonocore, M. H., & Gao, L.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1997-07
- Volume
- 38
- Issue
- 1
- Pages
- 89-100
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2041987174
- Cited by
- 170
- References
- 0
- FWCI
- 7.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.