MR microscopy of transgenic mice that spontaneously acquire experimental allergic encephalomyelitis
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Pathology of fixed spinal cords from transgenic mice with a myelin basic protein (MBP) specific T cell receptor was investigated. These mice spontaneously acquire the demyelinating disease experimental allergic encephalomyelitis (EAE). Several complementary imaging modalities, all on the same tissues, were used to visualize lesions; these included high‐field (11.7‐T) microscopic diffusion tensor imaging (DTI),T‐weighted imaging, and optical microscopy on histological sections. Lesions were predominantly in white matter around meninges and vasculature and appeared hyperintense in anatomical images. DTIs showed reduced diffusion anisotropy in the same hyperintense regions, consistent with inflammation and edema. Histology in the same tissues exhibited the characteristic pathology of EAE. Two techniques for visualizing the effective diffusion tensor fields are presented, which display direction, organization, and integrity of neuronal fibers. It is shown that DTI offers intriguing possibilities for visualizing axonal organization and lesions within white matter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Basser, P. J., & Pierpaoli, C. (1996) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1996.0086 · Cited by 4,306
Diffusion tensor MR imaging of the human brain
Pierpaoli, C., Jezzard, P., Basser, P. J., Barnett, A., & Di Chiro, G. (1996) · Radiology · doi:10.1148/radiology.201.3.8939209 · Cited by 2,664 · cited 2×
“evant for clinical imaging systems, in which gradient strength is often limited (47).”
An analytical model of restricted diffusion in bovine optic nerve
Stanisz, G. J., Wright, G. A., Henkelman, R. M., & Szafer, A. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370115 · Cited by 501
Cited by
The basis of anisotropic water diffusion in the nervous system—A technical review.
Beaulieu, C. (2002) · NMR in Biomedicine · doi:10.1002/nbm.782 · Cited by 4,628
Principles of diffusion tensor imaging and its applications to basic neuroscience research
Mori, S., & Zhang, J. (2006) · Neuron · doi:10.1016/j.neuron.2006.08.012 · Cited by 1,708
Diffusion‐tensor MRI: theory, experimental design and data analysis – a technical review
Basser, P. J., & Jones, D. K. (2002) · NMR in Biomedicine · doi:10.1002/nbm.783 · Cited by 1,478
Cohen, Y., & Assaf, Y. (2002) · NMR in Biomedicine · doi:10.1002/nbm.778 · Cited by 270
Apparent diffusion tensor measurements in myelin-deficient rat spinal cords
Gulani, V., Webb, A. G., Duncan, I. D., & Lauterbur, P. C. (2001) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200102)45:2<191::aid-mrm1025>3.0.co;2-9 · Cited by 251
“There has been added interest in this anisotropic diffusion phenomenon with the advent of diffusion tensor imaging (3,4), and its application in tracing fiber tracts (5–7), following ischemia (8–10), studying demyelinating diseases (11,12), and characterizing spinal cord injury (13).”
Background
Metadata
- Authors
- Ahrens, E. T., Laidlaw, D. H., Readhead, C., Brosnan, C. F., Fraser, S. E., & Jacobs, R. E.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1998-07
- Volume
- 40
- Issue
- 1
- Pages
- 119-132
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2060998642
- Cited by
- 86
- References
- 3
- FWCI
- 6.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: MR microscopy of transgenic mice that spontaneously acquire experimental allergic encephalomyelitis. https://app.cochat.ai/papers/10.1002/mrm.1910400117
- The paper
- Ahrens, E. T., Laidlaw, D. H., Readhead, C., Brosnan, C. F., Fraser, S. E., & Jacobs, R. E. (1998). MR microscopy of transgenic mice that spontaneously acquire experimental allergic encephalomyelitis. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910400117
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.