Exogenous contrast agent improves sensitivity of gradient‐echo functional magnetic resonance imaging at 9.4 T
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Relative to common clinical magnetic field strengths, higher fields benefit functional brain imaging both by providing additional signal for high‐resolution applications and by improving the sensitivity of endogenous contrast due to the blood oxygen level dependent (BOLD) mechanism, which has limited detection power at low magnetic fields relative to the use of exogenous contrast agent. This study evaluates the utility of iron oxide contrast agent for gradient echo functional MRI at 9.4 T in rodents using cocaine and methylphenidate as stimuli. Relative to the BOLD method, the use of high iron doses and short echo times provided a roughly twofold global increase in functional sensitivity, while also suppressing large vessel signal and reducing susceptibility artifacts. Furthermore, MRI measurements of the functional percentage change in cerebral blood volume (CBV) showed excellent agreement with results obtained at much lower magnetic field strengths, demonstrating that MRI estimates of this quantity are roughly independent of magnetic field when appropriate techniques are employed. The derived field dependencies for relative sensitivity and MRI estimates of the percentage change in CBV suggest that the benefits provided by exogenous agents will persist even at much higher magnetic fields than 9.4 T. Magn Reson Med 52:1272–1281, 2004. © 2004 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Imaging brain function in humans at 7 Tesla
Yacoub, E., Shmuel, A., Pfeuffer, J., Van De Moortele, P., Adriany, G., Andersen, P., Vaughan, J. T., Merkle, H., Ugurbil, K., & Hu, X. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1080 · Cited by 448
Cited by
Identifying neural drivers with functional MRI: an electrophysiological validation
David, O., Guillemain, I., Saillet, S., Reyt, S., Deransart, C., Segebarth, C., & Depaulis, A. (2008) · PLoS Biology · doi:10.1371/journal.pbio.0060315 · Cited by 533
“Variations in CBV-weighted signals y were assumed to be proportional and of opposite sign to variations of blood volume v—a CBV increase shortens the transverse relaxation time [72].”
BackgroundZhao, F., Wang, P., Hendrich, K., Ugurbil, K., & Kim, S.-G. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.11.013 · Cited by 266
Choi, J.-K., Chen, Y. I., Hamel, E., & Jenkins, B. G. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.10.029 · Cited by 200
Self-citationEkstrom, L. B., Roelfsema, P. R., Arsenault, J. T., Kolster, H., & Vanduffel, W. (2009) · The Journal of Neuroscience · doi:10.1523/jneurosci.0673-09.2009 · Cited by 83
Chen, Y. I., Wang, F.-N., Nelson, A. J., Xu, H., Kim, Y., Rosen, B. R., & Kwong, K. K. (2008) · Neuroscience Letters · doi:10.1016/j.neulet.2008.08.033 · Cited by 7
“Since the rCBV measurement is insensitive to the magnetic field strength [24], this study was carried out using 4.”
MethodSelf-citation
Metadata
- Authors
- Mandeville, J. B., Jenkins, B. G., Chen, Y. I., Choi, J., Kim, Y. R., Belen, D., Liu, C., Kosofsky, B. E., & Marota, J. J. A.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2004-11-23
- Volume
- 52
- Issue
- 6
- Pages
- 1272-1281
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1986312314
- Cited by
- 90
- References
- 1
- FWCI
- 5.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.