Cited by 1,880Advanced Neuroimaging Techniques and ApplicationsAdvanced MRI Techniques and ApplicationsNMR spectroscopy and applications

The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.

Q-ball imaging

Tuch, David S.·2004·Magnetic Resonance in Medicine

Abstract

Magnetic resonance diffusion tensor imaging (DTI) provides a powerful tool for mapping neural histoarchitecture in vivo. However, DTI can only resolve a single fiber orientation within each imaging voxel due to the constraints of the tensor model. For example, DTI cannot resolve fibers crossing, bending, or twisting within an individual voxel. Intravoxel fiber crossing can be resolved using q-space diffusion imaging, but q-space imaging requires large pulsed field gradients and time-intensive sampling. It is also possible to resolve intravoxel fiber crossing using mixture model decomposition of the high angular resolution diffusion imaging (HARDI) signal, but mixture modeling requires a model of the underlying diffusion process.Recently, it has been shown that the HARDI signal can be reconstructed model-independently using a spherical tomographic inversion called the Funk-Radon transform, also known as the spherical Radon transform. The resulting imaging method, termed q-ball imaging, can resolve multiple intravoxel fiber orientations and does not require any assumptions on the diffusion process such as Gaussianity or multi-Gaussianity. The present paper reviews the theory of q-ball imaging and describes a simple linear matrix formulation for the q-ball reconstruction based on spherical radial basis function interpolation. Open aspects of the q-ball reconstruction algorithm are discussed.

Overview

Integrity signals

Registry

Crossref · 10.1002/mrm.20279

Cites

43 of 43 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Flagged first, then by citations

Show all 43 references

Research works printed but not linked: 1

  1. Fasshauer GE, 1998, Mathematical Methods for Curves and Surfaces II, Innovations in Applied Mathematics, 117

Cited by

Sorted by citations

Items 901–1,000 of 1,002

Metadata

Authors
Tuch, D. S.
Affiliations
Massachusetts General Hospital (US)
Corresponding author
Tuch, David S.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2004-11-23
Volume
52
Issue
6
Pages
1358-1372
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W1988954604
Cited by
1,880
References
43
Citations by year
2026: 19 · 2025: 39 · 2024: 55 · 2023: 47 · 2022: 57 · 2021: 80 · 2020: 86 · 2019: 81 · 2018: 100 · 2017: 106 · 2016: 97 · 2015: 116 · 2014: 126 · 2013: 148 · 2012: 141
FWCI
38.55
Type
journal article
Language
en
Open access
closed
Locations
  • Magnetic Resonance in Medicine (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Institute of Neurological Disorders and Stroke (K25NS046532, NS46532)
  • National Center for Research Resources (RR 14075, P41RR014075)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced Neuroimaging Techniques and Applications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
  • Physical Sciences › Chemistry › Spectroscopy › NMR spectroscopy and applications
Keywords
Q-ball imaging, spherical Radon transform, high angular resolution diffusion imaging, fiber orientation distribution, diffusion MRI reconstruction
MeSH terms
Algorithms, Brain Mapping, Humans, Image Processing, Computer-Assisted, Diffusion Magnetic Resonance Imaging

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review