Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 247

The DOI matches its Crossref record.

Self‐navigated interleaved spiral (SNAILS): Application to high‐resolution diffusion tensor imaging

Open access
Liu, Chunlei, Bammer, Roland, Kim, Dong‐hyun, Moseley, Michael E.·2004·Magnetic Resonance in Medicine

Abstract

A fat‐saturated twice‐refocused spin echo sequence was implemented on a GE Signa 1.5‐T whole‐body system for diffusion‐weighted imaging. Data were acquired using an analytically designed interleaved variable‐density (VD) spiral readout trajectory. This flexible design algorithm allowed real‐time prescription on the scanner. Each interleaf of the VD spiral oversampled the center of k‐space. The oversampling provided an inherent motion compensation capability. The resultant diffusion‐weighted images showed good quality without any retrospective motion correction. An iterated motion correction algorithm was developed to further reduce the signal cancellation artifact caused by motion‐induced phase error. In this algorithm, a low‐resolution phase map was estimated using the oversampled data in the center of k‐space in order to correct for phase error in image space. In vivo diffusion tensor imaging (DTI) studies were performed on the brains of healthy volunteers. High‐quality isotropic diffusion‐weighted images, trace maps, and FA maps from axial, sagittal, and coronal slices were obtained using a VD spiral readout trajectory with matrix size 256 × 256. To our knowledge, this was also the first time in vivo 512 × 512 DTI results were reported. Magn Reson Med 52:1388–1396, 2004. © 2004 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.20288

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 247

Metadata

Authors
Liu, C., Bammer, R., Kim, D., & Moseley, M. E.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2004-11-23
Volume
52
Issue
6
Pages
1388-1396
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2080439432
Cited by
247
References
0
FWCI
4.81
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Self‐navigated interleaved spiral (SNAILS): Application to high‐resolution diffusion tensor imaging. https://app.cochat.ai/papers/10.1002/mrm.20288
The paper
Liu, C., Bammer, R., Kim, D., & Moseley, M. E. (2004). Self‐navigated interleaved spiral (SNAILS): Application to high‐resolution diffusion tensor imaging. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.20288

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.