Quantitative magnetic resonance spectroscopy: Semi‐parametric modeling and determination of uncertainties
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A semi‐parametric approach for the quantitative analysis of magnetic resonance (MR) spectra is proposed and an uncertainty analysis is given. Single resonances are described by parametric models or by parametrized in vitro spectra and the baseline is determined nonparametrically by regularization. By viewing baseline estimation in a reproducing kernel Hilbert space, an explicit parametric solution for the baseline is derived. A Bayesian point of view is adopted to derive uncertainties, and the many parameters associated with the baseline solution are treated as nuisance parameters. The derived uncertainties formally reduce to Cramér–Rao lower bounds for the parametric part of the model in the case of a vanishing baseline. The proposed uncertainty calculation was applied to simulated and measured MR spectra and the results were compared to Cramér–Rao lower bounds derived after the nonparametrically estimated baselines were subtracted from the spectra. In particular, for high SNR and strong baseline contributions the proposed procedure yields a more appropriate characterization of the accuracy of parameter estimates than Cramér–Rao lower bounds, which tend to overestimate accuracy. Magn Reson Med 53:1288–1296, 2005. © 2005 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spline Models for Observational Data
Wahba, G. (1990) · doi:10.1137/1.9781611970128 · Cited by 4,184
The Return of the Frequency Sweep: Designing Adiabatic Pulses for Contemporary NMR
Garwood, M., & DelaBarre, L. (2001) · Journal of Magnetic Resonance · doi:10.1006/jmre.2001.2340 · Cited by 952
Cited by
Colla, M., Schubert, F., Bubner, M., Heidenreich, J. O., Bajbouj, M., Seifert, F., Luborzewski, A., Heuser, I., & Kronenberg, G. (2009) · Molecular Psychiatry · doi:10.1038/mp.2008.26 · Cited by 106
Self-citationRegion-specific glutamate changes in patients with unipolar depression
Grimm, S., Luborzewski, A., Schubert, F., Merkl, A., Kronenberg, G., Colla, M., Heuser, I., & Bajbouj, M. (2012) · Journal of Psychiatric Research · doi:10.1016/j.jpsychires.2012.04.018 · Cited by 52
“The resulting spectrum was quantified using a program package that relies on a time domain-frequency domain fitting procedure involving inclusion of phantom basis spectra and prior knowledge, and background estimation by regularization (Schubert et al., 2004; Elster et al., 2005).”
MethodSelf-citationCreatine as a Novel Treatment for Depression in Females Using Methamphetamine: A Pilot Study
Hellem, T. L., Sung, Y.-H., Shi, X.-F., Pett, M. A., Latendresse, G., Morgan, J., Huber, R. S., Kuykendall, D., Lundberg, K. J., & Renshaw, P. F. (2015) · Journal of Dual Diagnosis · doi:10.1080/15504263.2015.1100471 · Cited by 49
“…at baseline to 1.22 at the end of treatment, she reported only missing one dose of creatine, returned the exact number of empty creatine bottles that were dispensed, and attended 86% of study visits, the uncertainty of measurement (Elster et al., 2005) might explain the decrease in phosphocreatine.”
BackgroundInfluential
Metadata
- Authors
- Elster, C., Schubert, F., Link, A., Walzel, M., Seifert, F., & Rinneberg, H.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2005-05-19
- Volume
- 53
- Issue
- 6
- Pages
- 1288-1296
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2039396477
- Cited by
- 45
- References
- 2
- FWCI
- 4.29
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative magnetic resonance spectroscopy: Semi‐parametric modeling and determination of uncertainties. https://app.cochat.ai/papers/10.1002/mrm.20500
- The paper
- Elster, C., Schubert, F., Link, A., Walzel, M., Seifert, F., & Rinneberg, H. (2005). Quantitative magnetic resonance spectroscopy: Semi‐parametric modeling and determination of uncertainties. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.20500
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.