The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Magnetic resonance imaging of cardiomyocyte apoptosis with a novel magneto‐optical nanoparticle
Open accessAbstract
The ability to image cardiomyocyte apoptosis in vivo with high‐resolution MRI could facilitate the development of novel cardioprotective therapies. The sensitivity of the novel nanoparticle AnxCLIO‐Cy5.5 for cardiomyocyte apoptosis was thus compared in vitro to that of annexin V‐FITC and showed a high degree of colocalization. MRI was then performed, following transient coronary artery (LAD) occlusion, in five mice given AnxCLIO‐Cy5.5 and in four mice given an identical dose (2 mg Fe/kg) of CLIO‐Cy5.5. MR signal intensity and myocardial T2* were evaluated, in vivo, in hypokinetic regions of myocardium in the LAD distribution. Ex vivo fluorescence imaging was performed to confirm the in vivo findings. Myocardial T2* was significantly lower in the mice given AnxCLIO‐Cy5.5 (8.1 versus 13.2 ms, P < 0.01), and fluorescence target to background ratio was significantly higher (2.1 versus 1.1, P < 0.01). This study thus demonstrates the feasibility of obtaining high‐resolution MR images of cardiomyocyte apoptosis in vivo with the novel nanoparticle, AnxCLIO‐Cy5.5. Magn Reson Med, 2005. © 2005 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Apoptosis in human acute myocardial infarction.
Saraste, A., Pulkki, K., Kallajoki, M., Henriksen, K., Parvinen, M., & Voipio-Pulkki, L.-M. (1997) · Circulation · doi:10.1161/01.cir.95.2.320 · Cited by 825 · cited 2×
“CM apoptosis is thought to play a central role in several disease processes involving the heart including ischemia (1,2), reperfusion injury (3,4), and heart failure (5,6).”
Background
Cited by
Laurent, S., Forge, D., Port, M., Roch, A., Robic, C., Vander Elst, L., & Muller, R. N. (2008) · Chemical Reviews · doi:10.1021/cr068445e · Cited by 6,852
Mahmoudi, M., Sant, S., Wang, B., Laurent, S., & Sen, T. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2010.05.006 · Cited by 1,881
Chemistry of MRI Contrast Agents: Current Challenges and New Frontiers
Wahsner, J., Gale, E. M., Rodríguez-Rodríguez, A., & Caravan, P. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00363 · Cited by 1,603
Recent advances in iron oxide nanocrystal technology for medical imaging☆
COROT, C., ROBERT, P., IDEE, J., & PORT, M. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.09.013 · Cited by 1,465
Multimodality Imaging Probes: Design and Challenges
Louie, A. (2010) · Chemical Reviews · doi:10.1021/cr9003538 · Cited by 1,044
Metadata
- Authors
- Sosnovik, D. E., Schellenberger, E. A., Nahrendorf, M., Novikov, M. S., Matsui, T., Dai, G., Reynolds, F., Grazette, L., Rosenzweig, A., Weissleder, R., & Josephson, L.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2005-08-05
- Volume
- 54
- Issue
- 3
- Pages
- 718-724
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1993157780
- Cited by
- 236
- References
- 1
- FWCI
- 15.24
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.