The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
High resolution pHe imaging of rat glioma using pH‐dependent relaxivity
Open accessAbstract
Previous studies using MR spectroscopy have shown that the extracellular pH (pH e) of tumors is acidic compared to normal tissues. This has a number of important sequelae that favor the emergence of more aggressive and therapy‐resistant tumors. New MRI methods based on pH‐sensitive T 1 relaxivity are an attractive alternative to previous spectroscopic methods, as they allow improvements in spatial and temporal resolution. Recently, pH‐dependent GdDOTA‐4AmP 5‐ and a pH‐independent analog, GdDOTP 5‐, were used to image renal pH in mice. The current study has used a similar approach to image pH e in rat gliomas. Significant differences were observed compared to the renal study. First, the relaxivity of GdDOTP 5‐ was found to be affected by the higher extracellular protein content of tumors. Second, the pixel‐by‐pixel analysis of the GdDOTP 5‐ and GdDOTA‐4AmP 5‐ pharmacokinetics showed significant dispersion, likely due to the temporal fluctuations in tumor perfusion. However, there was a robust correlation between the maximal enhancements produced by the two boluses. Therefore, to account for the local time‐courses differences, pH e maps were calculated at the time of maximal enhancement in each pixel. Finally, the comparison of the pH e and the time to maximal intensity maps revealed an inverse relationship between pH e and tumor perfusion. Magn Reson Med, 2006. © 2006 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An exploratory technique for investigating large quantities of categorical data
Kass, G. V. (1980) · Applied Statistics · doi:10.2307/2986296 · Cited by 2,880
Cited by
Chemistry of MRI Contrast Agents: Current Challenges and New Frontiers
Wahsner, J., Gale, E. M., Rodríguez-Rodríguez, A., & Caravan, P. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00363 · Cited by 1,603
Acidic extracellular microenvironment and cancer
Kato, Y., Ozawa, S., Miyamoto, C., Maehata, Y., Suzuki, A., Maeda, T., & Baba, Y. (2013) · Cancer Cell International · doi:10.1186/1475-2867-13-89 · Cited by 1,300
Application of Metal Coordination Chemistry To Explore and Manipulate Cell Biology
Haas, K. L., & Franz, K. J. (2009) · Chemical Reviews · doi:10.1021/cr900134a · Cited by 984
Causes and Consequences of Increased Glucose Metabolism of Cancers
Gillies, R. J., Robey, I., & Gatenby, R. A. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.047258 · Cited by 623
Self-citationLing, D., Park, W., Park, S.-J., Lu, Y., Kim, K. S., Hackett, M. J., Kim, B. H., Yim, H., Jeon, Y. S., Na, K., et al. (2014) · Journal of the American Chemical Society · doi:10.1021/ja4108287 · Cited by 517
Metadata
- Authors
- Garcia‐Martin, M. L., Martinez, G. V., Raghunand, N., Sherry, A. D., Zhang, S., & Gillies, R. J.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2006-01-09
- Volume
- 55
- Issue
- 2
- Pages
- 309-315
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2082774686
- Cited by
- 164
- References
- 1
- FWCI
- 7.30
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High resolution pHe imaging of rat glioma using pH‐dependent relaxivity. https://app.cochat.ai/papers/10.1002/mrm.20773
- The paper
- Garcia‐Martin, M. L., Martinez, G. V., Raghunand, N., Sherry, A. D., Zhang, S., & Gillies, R. J. (2006). High resolution pHe imaging of rat glioma using pH‐dependent relaxivity. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.20773
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.