CoChat

Diffusion of myelin water

Andrews, Trevor J., Osborne, Michael T., Does, Mark D. · 2006 · Magnetic Resonance in Medicine
Cited by 44

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

We studied compartmentally specific characteristics of water diffusion in excised frog sciatic nerve by combining T1 or T2 selective acquisitions with pulse‐gradient spin‐echo (PGSE) diffusion weighting, with the specific objective of characterizing myelin water diffusion. Combining a PGSE with a Carr‐Purcell‐Meiboom‐Gill (CPMG) acquisition provided apparent diffusion coefficients (ADCs) for each of the three T2 components found in nerve, including the short‐lived component believed to be derived from myelin water. Double‐inversion‐recovery (DIR) preparation provided an alternate means of discriminating myelin water, and in combination with PGSE provided somewhat different measures of ADC. The DIR measures yielded myelin water ADCs of 0.37 μm 2/ms (parallel to nerve) and 0.13 μm 2/ms (perpendicular to nerve). These ADC estimates were postulated to be more accurate than those based on T2 discrimination, although the difference between the two findings is not clear. Magn Reson Med, 2006. © 2006 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.20945

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Andrews, T. J., Osborne, M. T., & Does, M. D.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2006-06-09
Volume
56
Issue
2
Pages
381-385
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2046066110
Cited by
44
References
1
FWCI
3.27
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.