Abstract
This paper uses the theory of Cramer‐Rao lower bounds (CRLB) to obtain optimal acquisition schemes for in vivo quantitative magnetization transfer (MT) imaging, although the method is generally applicable to any multiparametric MRI technique. Quantitative MT fits a two‐pool model to data collected at different sampling points or settings of amplitude and offset frequency in the MT saturation pulses. Here we use simple objective functions based on the CRLB to optimize sampling strategies for multiple parameters simultaneously, and use simulated annealing to minimize these objective functions with respect to the sampling configuration. Experiments compare optimal schemes derived for quantitative MT in the human white matter (WM) at 1.5T with previously published schemes using both synthetic and human‐brain data. Results show large reductions in error of the fitted parameters with the new schemes, which greatly increases the clinical potential of in vivo quantitative MT. Since the sampling‐scheme optimization requires specific settings of the MT parameters, we also show that the optimum schemes are robust to these settings within the range of MT parameters observed in the brain. Magn Reson Med, 2006. © 2006 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912
Cited by
White matter integrity, fiber count, and other fallacies: The do's and don'ts of diffusion MRI
Jones, D. K., Knösche, T. R., & Turner, R. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.081 · Cited by 2,402
Alexander, A. L., Hurley, S. A., Samsonov, A. A., Adluru, N., Hosseinbor, A. P., Mossahebi, P., Tromp, D. P. M., Zakszewski, E., & Field, A. S. (2011) · Brain Connectivity · doi:10.1089/brain.2011.0071 · Cited by 449
Imaging brain microstructure with diffusion MRI: practicality and applications
Alexander, D. C., Dyrby, T. B., Nilsson, M., & Zhang, H. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3841 · Cited by 424
Self-citationDe Santis, S., Drakesmith, M., Bells, S., Assaf, Y., & Jones, D. K. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.12.003 · Cited by 231
Lampinen, B., Szczepankiewicz, F., Mårtensson, J., van Westen, D., Hansson, O., Westin, C., & Nilsson, M. (2020) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28216 · Cited by 86
Metadata
- Authors
- Cercignani, M., & Alexander, D. C.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2006-08-10
- Volume
- 56
- Issue
- 4
- Pages
- 803-810
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1982438030
- Cited by
- 98
- References
- 1
- FWCI
- 2.27
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimal acquisition schemes for in vivo quantitative magnetization transfer MRI. https://app.cochat.ai/papers/10.1002/mrm.21003
- The paper
- Cercignani, M., & Alexander, D. C. (2006). Optimal acquisition schemes for in vivo quantitative magnetization transfer MRI. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.21003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.