The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Hyperpolarized 3He diffusion MRI and histology in pulmonary emphysema
Open accessAbstract
Diffusion MRI of hyperpolarized 3 He shows that the apparent diffusion coefficient (ADC) of 3 He gas is highly restricted in the normal lung and becomes nearly unrestricted in severe emphysema. The nature of this restricted diffusion provides information about lung structure; however, no direct comparison with histology in human lungs has been reported. The purpose of this study is to provide information about 3 He gas diffusivity in explanted human lungs, and describe the relationship between 3 He diffusivity and the surface area to lung volume ratio (SA/V) and mean linear intercept (L m) measurements—the gold standard for diagnosis of emphysema. Explanted lungs from patients who were undergoing lung transplantation for advanced COPD, and donor lungs that were not used for transplantation were imaged via 3 He diffusion MRI. Histological measurements were made on the same specimens after they were frozen in the position of study. There is an inverse correlation between diffusivity and SA/V (and a positive correlation between diffusivity and L m). An important result is that restricted 3 He diffusivity separated normal from emphysematous lung tissue more clearly than the morphometric analyses. This effect may be due to the smaller histologic sampling size compared to the MRI voxel sizes. Magn Reson Med, 2006. © 2006 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vestbo, J., Hurd, S. S., Agustí, A. G., Jones, P. W., Vogelmeier, C., Anzueto, A., Barnes, P. J., Fabbri, L. M., Martinez, F. J., Nishimura, M., et al. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201204-0596pp · Cited by 15,983
Cited by
Hsia, C. C. W., Hyde, D. M., Ochs, M., & Weibel, E. R. (2010) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200809-1522st · Cited by 902
Schittny, J. C. (2017) · Cell and Tissue Research · doi:10.1007/s00441-016-2545-0 · Cited by 677
Narayanan, M., Owers-Bradley, J., Beardsmore, C. S., Mada, M., Ball, I., Garipov, R., Panesar, K. S., Kuehni, C. E., Spycher, B. D., Williams, S. E., et al. (2012) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201107-1348oc · Cited by 293
Jespersen, S. N., Bjarkam, C. R., Nyengaard, J. R., Chakravarty, M. M., Hansen, B., Vosegaard, T., Østergaard, L., Yablonskiy, D., Nielsen, N. C., & Vestergaard-Poulsen, P. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.08.053 · Cited by 290
Self-citationKnudsen, L., Weibel, E. R., Gundersen, H. J. G., Weinstein, F. V., & Ochs, M. (2010) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01100.2009 · Cited by 281
Metadata
- Authors
- Woods, J. C., Choong, C. K., Yablonskiy, D. A., Bentley, J., Wong, J., Pierce, J. A., Cooper, J. D., Macklem, P. T., Conradi, M. S., & Hogg, J. C.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2006-10-20
- Volume
- 56
- Issue
- 6
- Pages
- 1293-1300
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2097351207
- Cited by
- 205
- References
- 1
- FWCI
- 7.95
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.