The DOI matches its Crossref record.
Real‐time shimming to compensate for respiration‐induced B0 fluctuations
Abstract
In MRI of human brain, the respiratory cycle can induce B0‐field fluctuations through motion of the chest and fluctuations in local oxygen concentration. The associated NMR frequency changes can affect the MRI data in various ways and lead to temporal signal fluctuations, and image artifacts such as ghosting and blurring. Since the size of the effect scales with magnetic field strength, artifacts become particularly problematic at fields above 3.0T. Furthermore, the spatial dependence of the B0‐field fluctuations complicates their correction. In this work, a new method is presented that allows compensation of field fluctuations by modulating the B0 shims in real time. In this method, a reference scan is acquired to measure the spatial distribution of the B0 effect related to chest motion. During the actual scan, this information is then used, together with chest motion data, to apply compensating B0 shims in real time. The method can be combined with any type of scan without modifications to the pulse sequence. Real‐time B0 shimming is demonstrated to substantially improve the phase stability of EPI data and the image quality of multishot gradient‐echo (GRE) MRI at 7T. Magn Reson Med 57:362–368, 2007. © 2007 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Resting-state fMRI confounds and cleanup
Murphy, K., Birn, R. M., & Bandettini, P. A. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.001 · Cited by 666
Magnetic susceptibility mapping of brain tissue in vivo using MRI phase data
Shmueli, K., de Zwart, J. A., van Gelderen, P., Li, T., Dodd, S. J., & Duyn, J. H. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22135 · Cited by 527
Self-citationMRI‐based myelin water imaging: A technical review
Alonso‐Ortiz, E., Levesque, I. R., & Pike, G. B. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25198 · Cited by 285
Susceptibility contrast in high field MRI of human brain as a function of tissue iron content
Yao, B., Li, T.-Q., Gelderen, P. V., Shmueli, K., de Zwart, J. A., & Duyn, J. H. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.10.029 · Cited by 282
Self-citationfMRI at 1.5, 3 and 7 T: Characterising BOLD signal changes
van der Zwaag, W., Francis, S., Head, K., Peters, A., Gowland, P., Morris, P., & Bowtell, R. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.05.015 · Cited by 281
Metadata
- Authors
- van Gelderen, P., de Zwart, J. A., Starewicz, P., Hinks, R. S., & Duyn, J. H.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2007-01-26
- Volume
- 57
- Issue
- 2
- Pages
- 362-368
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2015136199
- Cited by
- 193
- References
- 0
- FWCI
- 7.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Real‐time shimming to compensate for respiration‐induced B0 fluctuations. https://app.cochat.ai/papers/10.1002/mrm.21136
- The paper
- van Gelderen, P., de Zwart, J. A., Starewicz, P., Hinks, R. S., & Duyn, J. H. (2007). Real‐time shimming to compensate for respiration‐induced B0 fluctuations. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.21136
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.