Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 159

The DOI matches its Crossref record.

Quantitative magnetization transfer imaging via selective inversion recovery with short repetition times

Open access
Gochberg, Daniel F., Gore, John C. · 2007 · Magnetic Resonance in Medicine

Abstract

Quantitative magnetization transfer imaging (qMTI) methods are able to estimate fundamental sample parameters, such as the relative size of the solid‐like macromolecular proton pool and the spin exchange rate between this pool and the directly measured free water protons. One such method is selective inversion recovery (SIR), in which the free water protons are selectively inverted and the signal is fit to a biexponential function of the inversion time (TI). SIR uses only low‐power pulses and requires no separate RF (B1) or static field (B0) field maps, and the analysis is largely independent of the macromolecular pool lineshape. These are all advantages over steady‐state off‐resonance saturation qMTI methods. However, up to now, SIR has been implemented only with repetition times TR ≫ T1. This paper describes a modification of SIR with smaller TR values and a greater signal‐to‐noise ratio (SNR) efficiency. Magn Reson Med 57:437–441, 2007. © 2007 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.21143

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Gochberg, D. F., & Gore, J. C.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2007-01-26
Volume
57
Issue
2
Pages
437-441
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2047538896
Cited by
159
References
0
FWCI
4.10
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.