Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 190

The DOI matches its Crossref record.

Reduced field‐of‐view MRI using outer volume suppression for spinal cord diffusion imaging

Wilm, B.J., Svensson, J., Henning, A., Pruessmann, K.P., Boesiger, P., Kollias, S.S. · 2007 · Magnetic Resonance in Medicine

Abstract

A spin‐echo single‐shot echo‐planar imaging (SS‐EPI) technique with a reduced field of view (FOV) in the phase‐encoding direction is presented that simultaneously reduces susceptibility effects and motion artifacts in diffusion‐weighted (DW) imaging (DWI) of the spinal cord at a high field strength (3T). To minimize aliasing, an outer volume suppression (OVS) sequence was implemented. Effective fat suppression was achieved with the use of a slice‐selection gradient‐reversal technique. The OVS was optimized by numerical simulations with respect to T1 relaxation times and B1 variations. The optimized sequence was evaluated in vitro and in vivo. In simulations the optimized OVS showed suppression to <0.25% and ∼3% in an optimal and worst‐case scenario, respectively. In vitro measurements showed a mean residual signal of <0.95% ± 0.42 for all suppressed areas. In vivo acquisition with 0.9 × 1.05 mm 2 in‐plane resolution resulted in artifact‐free images. The short imaging time of this technique makes it promising for clinical studies. Magn Reson Med 57:625–630, 2007. © 2007 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.21167

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Wilm, B. J., Svensson, J., Henning, A., Pruessmann, K. P., Boesiger, P., & Kollias, S. S.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2007-02-26
Volume
57
Issue
3
Pages
625-630
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2126796600
Cited by
190
References
0
FWCI
5.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.