The DOI matches its Crossref record.
Reduced field‐of‐view MRI using outer volume suppression for spinal cord diffusion imaging
Abstract
A spin‐echo single‐shot echo‐planar imaging (SS‐EPI) technique with a reduced field of view (FOV) in the phase‐encoding direction is presented that simultaneously reduces susceptibility effects and motion artifacts in diffusion‐weighted (DW) imaging (DWI) of the spinal cord at a high field strength (3T). To minimize aliasing, an outer volume suppression (OVS) sequence was implemented. Effective fat suppression was achieved with the use of a slice‐selection gradient‐reversal technique. The OVS was optimized by numerical simulations with respect to T1 relaxation times and B1 variations. The optimized sequence was evaluated in vitro and in vivo. In simulations the optimized OVS showed suppression to <0.25% and ∼3% in an optimal and worst‐case scenario, respectively. In vitro measurements showed a mean residual signal of <0.95% ± 0.42 for all suppressed areas. In vivo acquisition with 0.9 × 1.05 mm 2 in‐plane resolution resulted in artifact‐free images. The short imaging time of this technique makes it promising for clinical studies. Magn Reson Med 57:625–630, 2007. © 2007 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
SCT: Spinal Cord Toolbox, an open-source software for processing spinal cord MRI data
De Leener, B., Lévy, S., Dupont, S. M., Fonov, V. S., Stikov, N., Louis Collins, D., Callot, V., & Cohen-Adad, J. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.10.009 · Cited by 621
Head and Neck Squamous Cell Carcinoma: Value of Diffusion-weighted MR Imaging for Nodal Staging
Vandecaveye, V., De Keyzer, F., Vander Poorten, V., Dirix, P., Verbeken, E., Nuyts, S., & Hermans, R. (2009) · Radiology · doi:10.1148/radiol.2511080128 · Cited by 340
The current state-of-the-art of spinal cord imaging: Methods
Stroman, P. W., Wheeler-Kingshott, C., Bacon, M., Schwab, J. M., Bosma, R., Brooks, J., Cadotte, D., Carlstedt, T., Ciccarelli, O., Cohen-Adad, J., et al. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.124 · Cited by 334
Self-citationQuantitative MRI and spectroscopy of bone marrow
Karampinos, D. C., Ruschke, S., Dieckmeyer, M., Diefenbach, M., Franz, D., Gersing, A. S., Krug, R., & Baum, T. (2018) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25769 · Cited by 285
Mapping brain networks in awake mice using combined optical neural control and fMRI
Desai, M., Kahn, I., Knoblich, U., Bernstein, J., Atallah, H., Yang, A., Kopell, N., Buckner, R. L., Graybiel, A. M., Moore, C. I., et al. (2011) · Journal of Neurophysiology · doi:10.1152/jn.00828.2010 · Cited by 274
DWI of the spinal cord with reduced FOV single‐shot EPI
Saritas, E. U., Cunningham, C. H., Lee, J. H., Han, E. T., & Nishimura, D. G. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21640 · Cited by 264
Spinal cord MRI in multiple sclerosis—diagnostic, prognostic and clinical value
Kearney, H., Miller, D. H., & Ciccarelli, O. (2015) · Nature Reviews Neurology · doi:10.1038/nrneurol.2015.80 · Cited by 235
Kamagata, K., Hatano, T., Okuzumi, A., Motoi, Y., Abe, O., Shimoji, K., Kamiya, K., Suzuki, M., Hori, M., Kumamaru, K. K., et al. (2016) · European Radiology · doi:10.1007/s00330-015-4066-8 · Cited by 135
Neurite orientation dispersion and density imaging of the healthy cervical spinal cord in vivo
Grussu, F., Schneider, T., Zhang, H., Alexander, D. C., & Wheeler–Kingshott, C. A. M. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.01.045 · Cited by 118
Metadata
- Authors
- Wilm, B. J., Svensson, J., Henning, A., Pruessmann, K. P., Boesiger, P., & Kollias, S. S.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2007-02-26
- Volume
- 57
- Issue
- 3
- Pages
- 625-630
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2126796600
- Cited by
- 190
- References
- 0
- FWCI
- 5.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.