Obtaining blood oxygenation levels from MR signal behavior in the presence of single venous vessels
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The MR signal decay in gradient echo sequences includes signal loss due to spin dephasing caused by static magnetic field inhomogeneities. This decay can be calculated for different geometries of the susceptibility distribution, such as spheres, cylinders, or cylinder networks. In particular, the model of an infinitely long cylinder is a good approximation for single straight blood vessels. Blood oxygenation and blood volume fraction are important parameters, which influence the signal in a characteristic way. In this work the signal decays for a single cylindrical vessel were investigated and evaluated in simulations, phantom measurements as well as in vivo measurements of small single veins in the human brain by using a 3D multiecho gradient echo sequence. Good agreement between simulations and phantom experiments was obtained for different experimental settings. Based on the simulations, physiologically consistent values of venous blood oxygenation level, Y, were extracted from the in vivo measurements of different veins and volunteers (Y = 0.55 ± 0.02). The methods ability to measure changes in venous blood oxygenation induced by carbogen breathing was demonstrated in one volunteer, where an increase from Y ≈ 0.5 to Y ≈ 0.7 was observed. Magn Reson Med 58:1035–1044, 2007. © 2007 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ogawa, S., Menon, R. S., Tank, D. W., Kim, S. G., Merkle, H., Ellermann, J. M., & Ugurbil, K. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81441-3 · Cited by 1,772 · cited 2×
“This influence of Y on the MR signal is called the blood oxygenation level dependent (BOLD)-effect (2) and it forms the basis of susceptibility weighted imaging (SWI) (3) and fMRI (1).”
BackgroundMethodTurner, R. (2002) · NeuroImage · doi:10.1006/nimg.2002.1082 · Cited by 365 · cited 1×
“The downstream dilution of blood oxygenation changes, away from the site of neural activation by draining veins, is known to limit spatial resolution in fMRI (25).”
Background
Cited by
Susceptibility-Weighted Imaging: Technical Aspects and Clinical Applications, Part 1
Haacke, E. M., Mittal, S., Wu, Z., Neelavalli, J., & Cheng, Y.-C. N. (2009) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1400 · Cited by 1,113
Langkammer, C., Schweser, F., Krebs, N., Deistung, A., Goessler, W., Scheurer, E., Sommer, K., Reishofer, G., Yen, K., Fazekas, F., et al. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.05.049 · Cited by 801
“In addition, substances such as blood and contributions from calcium and trace elements, have also been found to affect the magnetic susceptibility of tissue (Mitsumori et al., 2009; Schweser et al., 2011; Sedlacik et al., 2007; Shmueli et al., 2011; Yamada et al., 1996).”
Self-citationSchweser, F., Deistung, A., Lehr, B. W., & Reichenbach, J. R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.10.070 · Cited by 710
Self-citationDeistung, A., Rauscher, A., Sedlacik, J., Stadler, J., Witoszynskyj, S., & Reichenbach, J. R. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21754 · Cited by 169
Self-citationQuantitative oxygenation venography from MRI phase
Fan, A. P., Bilgic, B., Gagnon, L., Witzel, T., Bhat, H., Rosen, B. R., & Adalsteinsson, E. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24918 · Cited by 165
“Previous MRI studies have modeled cerebral veins as long cylinders to quantify blood oxygenation from T2* signal decay profiles internal and external to the vessel (11-13), as well as from phase signal differences between the vein and tissue (10,14).”
Multi-echo fMRI of the cortical laminae in humans at 7T
Koopmans, P. J., Barth, M., Orzada, S., & Norris, D. G. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.02.042 · Cited by 160
“This is mostly based upon the short T2⁎ relaxation time of blood in the resting state, i.e.witha relatively lowvenousbloodoxygenation level (Y) between 0.55 and 0.781 (Sedlacik et al., 2007; Silvennoinen et al., 2003; Spees et al., 2001; Vovenko, 1999; Weisskoff and Kiihne, 1992).”
InfluentialChristen, T., Pannetier, N. A., Ni, W. W., Qiu, D., Moseley, M. E., Schuff, N., & Zaharchuk, G. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.11.052 · Cited by 97
“The point-spread functionwill have a significant influence on the signal evolution, and should also be taken into account (Sedlacik et al., 2007).”
BackgroundDuyn, J. (2013) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2012.11.013 · Cited by 95
“In functional brain studies, analysis of the signal decay and frequency shifts associated with deoxyhemoglobin in the vasculature may allow the measurement of blood oxygenation [41,57].”
Background
Metadata
- Authors
- Sedlacik, J., Rauscher, A., & Reichenbach, J. R.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2007-10-29
- Volume
- 58
- Issue
- 5
- Pages
- 1035-1044
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2027384903
- Cited by
- 70
- References
- 2
- FWCI
- 4.79
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.