The DOI matches its Crossref record.
Fluorine‐19 MRI for visualization and quantification of cell migration in a diabetes model
Abstract
This article describes an in vivo imaging method for visualizing and quantifying a specific cell population. Cells are labeled ex vivo with a perfluoropolyether nanoparticle tracer agent and then detected in vivo using 19 F MRI following cell transfer. 19 F MRI selectively visualizes only the labeled cells with no background, and a conventional 1 H image taken in the same imaging session provides anatomical context. Using the nonobese diabetic mouse, an established model of type 1 diabetes, 19 F MRI data were acquired showing the early homing behavior of diabetogenic T cells to the pancreas. A computational algorithm provided T cell counts in the pancreas. Approximately 2% of the transferred cells homed to the pancreas after 48 hr. The technique allows for both unambiguous detection of labeled cells and quantification directly from the in vivo images. The in vivo quantification and cell trafficking patterns were verified using 19 F spectroscopy and fluorescence microscopy in excised pancreata. The labeling procedure did not affect T‐cell migration in vivo. This imaging platform is applicable to many cell types and disease models and can potentially be used for monitoring the trafficking of cellular therapeutics. Magn Reson Med 58:725–734, 2007. © 2007 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
19F Magnetic Resonance Imaging (MRI): From Design of Materials to Clinical Applications
Tirotta, I., Dichiarante, V., Pigliacelli, C., Cavallo, G., Terraneo, G., Bombelli, F. B., Metrangolo, P., & Resnati, G. (2015) · Chemical Reviews · doi:10.1021/cr500286d · Cited by 521
Fluorine (19F) MRS and MRI in biomedicine
Ruiz‐Cabello, J., Barnett, B. P., Bottomley, P. A., & Bulte, J. W. M. (2011) · NMR in Biomedicine · doi:10.1002/nbm.1570 · Cited by 489
Fluoropolymers in Biomedical Applications: State-of-the-Art and Future Perspectives
Lv, J., & Cheng, Y. (2021) · Chemical Society Reviews · doi:10.1039/d0cs00258e · Cited by 316
Metadata
- Authors
- Srinivas, M., Morel, P. A., Ernst, L. A., Laidlaw, D. H., & Ahrens, E. T.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2007-09-26
- Volume
- 58
- Issue
- 4
- Pages
- 725-734
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2101501385
- Cited by
- 259
- References
- 0
- FWCI
- 9.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fluorine‐19 MRI for visualization and quantification of cell migration in a diabetes model. https://app.cochat.ai/papers/10.1002/mrm.21352
- The paper
- Srinivas, M., Morel, P. A., Ernst, L. A., Laidlaw, D. H., & Ahrens, E. T. (2007). Fluorine‐19 MRI for visualization and quantification of cell migration in a diabetes model. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.21352
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.