The DOI matches its Crossref record.
Compressed sensing in dynamic MRI
Open accessAbstract
Recent theoretical advances in the field of compressive sampling—also referred to as compressed sensing (CS)—hold considerable promise for practical applications in MRI, but the fundamental condition of sparsity required in the CS framework is usually not fulfilled in MR images. However, in dynamic imaging, data sparsity can readily be introduced by applying the Fourier transformation along the temporal dimension assuming that only parts of the field‐of‐view (FOV) change at a high temporal rate while other parts remain stationary or change slowly. The second condition for CS, random sampling, can easily be realized by randomly skipping phase‐encoding lines in each dynamic frame. In this work, the feasibility of the CS framework for accelerated dynamic MRI is assessed. Simulated datasets are used to compare the reconstruction results for different reduction factors, noise, and sparsity levels. In vivo cardiac cine data and Fourier‐encoded velocity data of the carotid artery are used to test the reconstruction performance relative to k‐t broad‐use linear acquisition speed‐up technique (k‐t BLAST) reconstructions. Given sufficient data sparsity and base signal‐to‐noise ratio (SNR), CS is demonstrated to result in improved temporal fidelity compared to k‐t BLAST reconstructions for the example data sets used in this work. Magn Reson Med 59:365–373, 2008. © 2008 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sparse Signal Recovery With Temporally Correlated Source Vectors Using Sparse Bayesian Learning
Zhang, Z., & Rao, B. D. (2011) · IEEE Journal of Selected Topics in Signal Processing · doi:10.1109/jstsp.2011.2159773 · Cited by 868
Feng, L., Grimm, R., Block, K. T., Chandarana, H., Kim, S., Xu, J., Axel, L., Sodickson, D. K., & Otazo, R. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24980 · Cited by 718
Feng, L., Axel, L., Chandarana, H., Block, K. T., Sodickson, D. K., & Otazo, R. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25665 · Cited by 667
Compressed sensing reconstruction for magnetic resonance parameter mapping
Doneva, M., Börnert, P., Eggers, H., Stehning, C., Sénégas, J., & Mertins, A. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22483 · Cited by 326
Zhao, B., Haldar, J. P., Christodoulou, A. G., & Liang, Z.-P. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2203921 · Cited by 295
Metadata
- Authors
- Gamper, U., Boesiger, P., & Kozerke, S.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2008-01-28
- Volume
- 59
- Issue
- 2
- Pages
- 365-373
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2056775112
- Cited by
- 569
- References
- 0
- FWCI
- 21.98
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Compressed sensing in dynamic MRI. https://app.cochat.ai/papers/10.1002/mrm.21477
- The paper
- Gamper, U., Boesiger, P., & Kozerke, S. (2008). Compressed sensing in dynamic MRI. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.21477
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.