The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Regression algorithm correcting for partial volume effects in arterial spin labeling MRI
Abstract
Partial volume effects (PVE) are a consequence of limited spatial resolution in brain imaging. In arterial spin labeling (ASL) MRI, the problem is exacerbated by the nonlinear dependency of the ASL signal on magnetization contributions from each tissue within an imaged voxel. We have developed an algorithm that corrects for PVE in ASL imaging. The algorithm is based on a model that represents the voxel intensity as a weighted sum of pure tissue contribution, where the weighting coefficients are the tissue's fractional volume in the voxel. Using this algorithm, we were able to estimate cerebral blood flow (CBF) for gray matter (GM) and white matter (WM) independently. The average voxelwise ratio of GM to WM CBF was ∼3.2, in good agreement with reports in the literature. As proof of concept, data from PVE‐corrected method were compared with those from the conventional, PVE‐uncorrected method. As hypothesized, the two yielded similar CBF values for voxels containing >95% GM and differed in proportion with the voxels' heterogeneity. More importantly, the GM CBF assessed with the PVE‐corrected method was independent of the voxels' heterogeneity, implying that estimation of flow was unaffected by PVE. An example of application of this algorithm in motor‐activation data is also given. Magn Reson Med, 2008. © 2008 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Experimental Design: Procedures for the Behavioral Sciences
Kirk, R. (2013) · doi:10.4135/9781483384733 · Cited by 8,539
Experimental design and the relative sensitivity of BOLD and perfusion fMRI
Aguirre, G. K., Detre, J. A., Zarahn, E., & Alsop, D. C. (2002) · NeuroImage · doi:10.1006/nimg.2001.0990 · Cited by 403
Asllani, I., Habeck, C., Scarmeas, N., Borogovac, A., Brown, T. R., & Stern, Y. (2008) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/sj.jcbfm.9600570 · Cited by 172
Self-citation
Cited by
Arterial Spin Labeling Perfusion of the Brain: Emerging Clinical Applications
Haller, S., Zaharchuk, G., Thomas, D. L., Lovblad, K.-O., Barkhof, F., & Golay, X. (2016) · Radiology · doi:10.1148/radiol.2016150789 · Cited by 514
Age-associated reductions in cerebral blood flow are independent from regional atrophy
Chen, J. J., Rosas, H. D., & Salat, D. H. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.12.032 · Cited by 360
A neuroradiologist’s guide to arterial spin labeling MRI in clinical practice
Grade, M., Hernandez Tamames, J. A., Pizzini, F. B., Achten, E., Golay, X., & Smits, M. (2015) · Neuroradiology · doi:10.1007/s00234-015-1571-z · Cited by 298
Binnewijzend, M. A. A., Kuijer, J. P. A., Benedictus, M. R., van der Flier, W. M., Wink, A. M., Wattjes, M. P., van Berckel, B. N. M., Scheltens, P., & Barkhof, F. (2013) · Radiology · doi:10.1148/radiol.12120928 · Cited by 260
Perfusion Magnetic Resonance Imaging: A Comprehensive Update on Principles and Techniques
Jahng, G.-H., Li, K.-L., Ostergaard, L., & Calamante, F. (2014) · Korean Journal of Radiology · doi:10.3348/kjr.2014.15.5.554 · Cited by 256
Metadata
- Authors
- Asllani, I., Borogovac, A., & Brown, T. R.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2008-09-30
- Volume
- 60
- Issue
- 6
- Pages
- 1362-1371
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2160056785
- Cited by
- 241
- References
- 3
- FWCI
- 2.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Regression algorithm correcting for partial volume effects in arterial spin labeling MRI. https://app.cochat.ai/papers/10.1002/mrm.21670
- The paper
- Asllani, I., Borogovac, A., & Brown, T. R. (2008). Regression algorithm correcting for partial volume effects in arterial spin labeling MRI. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.21670
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.