CoChat

T2 relaxation time abnormalities in bipolar disorder and schizophrenia

Open access
Öngür, Dost, Prescot, Andrew P., Jensen, J. Eric, Rouse, Elizabeth D., Cohen, Bruce M., Renshaw, Perry F., Olson, David P. · 2010 · Magnetic Resonance in Medicine
Cited by 60

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

There are substantial abnormalities in the number, density, and size of cortical neurons and glial cells in bipolar disorder and schizophrenia. Because molecule‐microenvironment interactions modulate metabolite signals characteristics, these cellular abnormalities may impact transverse (T2) relaxation times. We measured T2 relaxation times for three intracellular metabolites (N‐acetylaspartate + N‐acetylaspartylglutamate, creatine + phosphocreatine, and choline‐containing compounds) in the anterior cingulate cortex and parieto‐occipital cortex from 20 healthy subjects, 15 patients with bipolar disorder, and 15 patients with schizophrenia at 4 T. Spectra used in T2 quantification were collected from 8‐cc voxels with varying echo times (30 to 500 ms, in 10‐ms steps). Both bipolar disorder and schizophrenia groups had numerically shorter T2 relaxation times than the healthy subjects group in both regions; these differences reached statistical significance for creatine + phosphocreatine and choline‐containing compounds in bipolar disorder and for choline‐containing compounds in schizophrenia. Metabolite T2 relaxation time shortening is consistent with reduced cell volumes and altered macromolecule structures, and with prolonged water T2 relaxation times reported in bipolar disorder and schizophrenia. These findings suggest that metabolite concentrations reported in magnetic resonance spectroscopy studies of psychiatric conditions may be confounded by T2 relaxation and highlight the importance of measuring and correcting for this variable. Magn Reson Med, 2009. © 2009 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.22148

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 60

Metadata

Authors
Öngür, D., Prescot, A. P., Jensen, J. E., Rouse, E. D., Cohen, B. M., Renshaw, P. F., & Olson, D. P.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2009-11-13
Volume
63
Issue
1
Pages
1-8
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2015237572
Cited by
60
References
3
FWCI
2.58
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.