PROMO: Real‐time prospective motion correction in MRI using image‐based tracking

Open access
White, Nathan, Roddey, Cooper, Shankaranarayanan, Ajit, Han, Eric, Rettmann, Dan, Santos, Juan, Kuperman, Josh, Dale, Anders·2010·Magnetic Resonance in Medicine

Abstract

Artifacts caused by patient motion during scanning remain a serious problem in most MRI applications. The prospective motion correction technique attempts to address this problem at its source by keeping the measurement coordinate system fixed with respect to the patient throughout the entire scan process. In this study, a new image‐based approach for prospective motion correction is described, which utilizes three orthogonal two‐dimensional spiral navigator acquisitions, along with a flexible image‐based tracking method based on the extended Kalman filter algorithm for online motion measurement. The spiral navigator/extended Kalman filter framework offers the advantages of image‐domain tracking within patient‐specific regions‐of‐interest and reduced sensitivity to off‐resonance‐induced corruption of rigid‐body motion estimates. The performance of the method was tested using offline computer simulations and online in vivo head motion experiments. In vivo validation results covering a broad range of staged head motions indicate a steady‐state error of less than 10% of the motion magnitude, even for large compound motions that included rotations over 15 deg. A preliminary in vivo application in three‐dimensional inversion recovery spoiled gradient echo (IR‐SPGR) and three‐dimensional fast spin echo (FSE) sequences demonstrates the effectiveness of the spiral navigator/extended Kalman filter framework for correcting three‐dimensional rigid‐body head motion artifacts prospectively in high‐resolution three‐dimensional MRI scans. Magn Reson Med, 2010. © 2009 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.22176

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 376

Metadata

Authors
White, N., Roddey, C., Shankaranarayanan, A., Han, E., Rettmann, D., Santos, J., Kuperman, J., & Dale, A.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2009-12-21
Volume
63
Issue
1
Pages
91-105
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W1986218154
Cited by
376
References
1
FWCI
10.80
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.