4D phase contrast MRI at 3 T: Effect of standard and blood‐pool contrast agents on SNR, PC‐MRA, and blood flow visualization

Open access
Bock, Jelena, Frydrychowicz, Alex, Stalder, Aurélien F., Bley, Thorsten A., Burkhardt, Hans, Hennig, Jürgen, Markl, Michael·2010·Magnetic Resonance in Medicine

Abstract

Time‐resolved phase contrast (PC) MRI with velocity encoding in three directions (flow‐sensitive four‐dimensional MRI) can be employed to assess three‐dimensional blood flow in the entire aortic lumen within a single measurement. These data can be used not only for the visualization of blood flow but also to derive additional information on vascular geometry with three‐dimensional PC MR angiography (MRA). As PC‐MRA is sensitive to available signal‐to‐noise ratio, standard and novel blood pool contrast agents may help to enhance PC‐MRA image quality. In a group of 30 healthy volunteers, the influence of different contrast agents on vascular signal‐to‐noise ratio, PC‐MRA quality, and subsequent three‐dimensional stream‐line visualization in the thoracic aorta was determined. Flow‐sensitive four‐dimensional MRI data acquired with contrast agent provided significantly improved signal‐to‐noise ratio in magnitude data and noise reduction in velocity data compared to measurements without contrast media. The agreement of three‐dimensional PC‐MRA with reference standard contrast‐enhanced MRA was good for both contrast agents, with improved PC‐MRA performance for blood pool contrast agent, particularly for the smaller supra‐aortic branches. For three‐dimensional flow visualization, a trend toward improved results for the data with contrast agent was observed. Magn Reson Med, 2010. © 2009 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.22199

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 166

Metadata

Authors
Bock, J., Frydrychowicz, A., Stalder, A. F., Bley, T. A., Burkhardt, H., Hennig, J., & Markl, M.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2009-12-18
Volume
63
Issue
2
Pages
330-338
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2076510657
Cited by
166
References
1
FWCI
7.75
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: 4D phase contrast MRI at 3 T: Effect of standard and blood‐pool contrast agents on SNR, PC‐MRA, and blood flow visualization. https://app.cochat.ai/papers/10.1002/mrm.22199
The paper
Bock, J., Frydrychowicz, A., Stalder, A. F., Bley, T. A., Burkhardt, H., Hennig, J., & Markl, M. (2010). 4D phase contrast MRI at 3 T: Effect of standard and blood‐pool contrast agents on SNR, PC‐MRA, and blood flow visualization. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.22199