The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
4D phase contrast MRI at 3 T: Effect of standard and blood‐pool contrast agents on SNR, PC‐MRA, and blood flow visualization
Open accessAbstract
Time‐resolved phase contrast (PC) MRI with velocity encoding in three directions (flow‐sensitive four‐dimensional MRI) can be employed to assess three‐dimensional blood flow in the entire aortic lumen within a single measurement. These data can be used not only for the visualization of blood flow but also to derive additional information on vascular geometry with three‐dimensional PC MR angiography (MRA). As PC‐MRA is sensitive to available signal‐to‐noise ratio, standard and novel blood pool contrast agents may help to enhance PC‐MRA image quality. In a group of 30 healthy volunteers, the influence of different contrast agents on vascular signal‐to‐noise ratio, PC‐MRA quality, and subsequent three‐dimensional stream‐line visualization in the thoracic aorta was determined. Flow‐sensitive four‐dimensional MRI data acquired with contrast agent provided significantly improved signal‐to‐noise ratio in magnitude data and noise reduction in velocity data compared to measurements without contrast media. The agreement of three‐dimensional PC‐MRA with reference standard contrast‐enhanced MRA was good for both contrast agents, with improved PC‐MRA performance for blood pool contrast agent, particularly for the smaller supra‐aortic branches. For three‐dimensional flow visualization, a trend toward improved results for the data with contrast agent was observed. Magn Reson Med, 2010. © 2009 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
4D flow cardiovascular magnetic resonance consensus statement
Dyverfeldt, P., Bissell, M., Barker, A. J., Bolger, A. F., Carlhäll, C.-J., Ebbers, T., Francios, C. J., Frydrychowicz, A., Geiger, J., Giese, D., et al. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0174-5 · Cited by 877
Self-citationMarkl, M., Frydrychowicz, A., Kozerke, S., Hope, M., & Wieben, O. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23632 · Cited by 788
Self-citationMarkl, M., Kilner, P. J., & Ebbers, T. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-7 · Cited by 463
Self-citation4D Flow cardiovascular magnetic resonance consensus statement: 2023 update
Bissell, M. M., Raimondi, F., Ait Ali, L., Allen, B. D., Barker, A. J., Bolger, A., Burris, N., Carhäll, C.-J., Collins, J. D., Ebbers, T., et al. (2023) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-023-00942-z · Cited by 296
Self-citationBorger, M. A., Fedak, P. W. M., Stephens, E. H., Gleason, T. G., Girdauskas, E., Ikonomidis, J. S., Khoynezhad, A., Siu, S. C., Verma, S., Hope, M. D., et al. (2018) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2018.02.115 · Cited by 287
Self-citation
Metadata
- Authors
- Bock, J., Frydrychowicz, A., Stalder, A. F., Bley, T. A., Burkhardt, H., Hennig, J., & Markl, M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2009-12-18
- Volume
- 63
- Issue
- 2
- Pages
- 330-338
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2076510657
- Cited by
- 166
- References
- 1
- FWCI
- 7.75
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 4D phase contrast MRI at 3 T: Effect of standard and blood‐pool contrast agents on SNR, PC‐MRA, and blood flow visualization. https://app.cochat.ai/papers/10.1002/mrm.22199
- The paper
- Bock, J., Frydrychowicz, A., Stalder, A. F., Bley, T. A., Burkhardt, H., Hennig, J., & Markl, M. (2010). 4D phase contrast MRI at 3 T: Effect of standard and blood‐pool contrast agents on SNR, PC‐MRA, and blood flow visualization. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.22199
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.