The DOI matches its Crossref record.
Diffusion imaging in humans at 7T using readout‐segmented EPI and GRAPPA
Open accessAbstract
Anatomical MRI studies at 7T have demonstrated the ability to provide high‐quality images of human tissue in vivo. However, diffusion‐weighted imaging at 7T is limited by the increased level of artifact associated with standard, single‐shot, echo‐planar imaging, even when parallel imaging techniques such as generalized autocalibrating partially parallel acquisitions (GRAPPA) are used to reduce the effective echo spacing. Readout‐segmented echo‐planar imaging in conjunction with parallel imaging has the potential to reduce these artifacts by allowing a further reduction in effective echo spacing during the echo‐planar imaging readout. This study demonstrates that this approach does indeed provide a substantial improvement in image quality by reducing image blurring and susceptibility‐based distortions, as well as by allowing the acquisition of diffusion‐weighted images with a high spatial resolution. A preliminary application of the technique to high‐resolution diffusion tensor imaging provided a high level of neuroanatomical detail, which should prove valuable in a wide range of applications. Magn Reson Med 64:9–14, 2010. © 2010 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Advances in diffusion MRI acquisition and processing in the Human Connectome Project
Sotiropoulos, S. N., Jbabdi, S., Xu, J., Andersson, J. L., Moeller, S., Auerbach, E. J., Glasser, M. F., Hernandez, M., Sapiro, G., Jenkinson, M., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.057 · Cited by 891
Tractography: Where Do We Go from Here?
Jbabdi, S., & Johansen-Berg, H. (2011) · Brain Connectivity · doi:10.1089/brain.2011.0033 · Cited by 614
Imaging brain microstructure with diffusion MRI: practicality and applications
Alexander, D. C., Dyrby, T. B., Nilsson, M., & Zhang, H. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3841 · Cited by 424
The Human Connectome Project and beyond: Initial applications of 300mT/m gradients
McNab, J. A., Edlow, B. L., Witzel, T., Huang, S. Y., Bhat, H., Heberlein, K., Feiweier, T., Liu, K., Keil, B., Cohen-Adad, J., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.074 · Cited by 359
Self-citationA guideline for head volume conductor modeling in EEG and MEG
Vorwerk, J., Cho, J.-H., Rampp, S., Hamer, H., Knösche, T. R., & Wolters, C. H. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.06.040 · Cited by 302
Self-citation
Metadata
- Authors
- Heidemann, R. M., Porter, D. A., Anwander, A., Feiweier, T., Heberlein, K., Knösche, T. R., & Turner, R.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2010-06-23
- Volume
- 64
- Issue
- 1
- Pages
- 9-14
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2152426879
- Cited by
- 172
- References
- 0
- FWCI
- 12.78
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diffusion imaging in humans at 7T using readout‐segmented EPI and GRAPPA. https://app.cochat.ai/papers/10.1002/mrm.22480
- The paper
- Heidemann, R. M., Porter, D. A., Anwander, A., Feiweier, T., Heberlein, K., Knösche, T. R., & Turner, R. (2010). Diffusion imaging in humans at 7T using readout‐segmented EPI and GRAPPA. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.22480
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.