The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Fast dynamic 3D MR spectroscopic imaging with compressed sensing and multiband excitation pulses for hyperpolarized 13C studies
Open accessAbstract
Hyperpolarized 13 C MR spectroscopic imaging can detect not only the uptake of the pre‐polarized molecule but also its metabolic products in vivo, thus providing a powerful new method to study cellular metabolism. Imaging the dynamic perfusion and conversion of these metabolites provides additional tissue information but requires methods for efficient hyperpolarization usage and rapid acquisitions. In this work, we have developed a time‐resolved 3D MR spectroscopic imaging method for acquiring hyperpolarized 13 C data by combining compressed sensing methods for acceleration and multiband excitation pulses to efficiently use the magnetization. This method achieved a 2 sec temporal resolution with full volumetric coverage of a mouse, and metabolites were observed for up to 60 sec following injection of hyperpolarized [1‐13 C]‐pyruvate. The compressed sensing acquisition used random phase encode gradient blips to create a novel random undersampling pattern tailored to dynamic MR spectroscopic imaging with sampling incoherency in four (time, frequency, and two spatial) dimensions. The reconstruction was also tailored to dynamic MR spectroscopic imaging by applying a temporal wavelet sparsifying transform to exploit the inherent temporal sparsity. Customized multiband excitation pulses were designed with a lower flip angle for the [1‐13 C]‐pyruvate substrate given its higher concentration than its metabolic products ([1‐13 C]‐lactate and [1‐13 C]‐alanine), thus using less hyperpolarization per excitation. This approach has enabled the monitoring of perfusion and uptake of the pyruvate, and the conversion dynamics to lactate and alanine throughout a volume with high spatial and temporal resolution. Magn Reson Med, 2011. © 2010 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
Self-citationMYC inactivation uncovers pluripotent differentiation and tumour dormancy in hepatocellular cancer
Shachaf, C. M., Kopelman, A. M., Arvanitis, C., Karlsson, Å., Beer, S., Mandl, S., Bachmann, M. H., Borowsky, A. D., Ruebner, B., Cardiff, R. D., et al. (2004) · Nature · doi:10.1038/nature03043 · Cited by 874
Cited by
Metabolic Imaging of Patients with Prostate Cancer Using Hyperpolarized [1- 13 C]Pyruvate
Nelson, S. J., Kurhanewicz, J., Vigneron, D. B., Larson, P. E. Z., Harzstark, A. L., Ferrone, M., van Criekinge, M., Chang, J. W., Bok, R., Park, I., et al. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3006070 · Cited by 1,286
Self-citationHyperpolarized 13C MRI: Path to Clinical Translation in Oncology
Kurhanewicz, J., Vigneron, D. B., Ardenkjaer-Larsen, J. H., Bankson, J. A., Brindle, K., Cunningham, C. H., Gallagher, F. A., Keshari, K. R., Kjaer, A., Laustsen, C., et al. (2019) · Neoplasia · doi:10.1016/j.neo.2018.09.006 · Cited by 440
Self-citationBREAKING THE COHERENCE BARRIER: A NEW THEORY FOR COMPRESSED SENSING
ADCOCK, B., HANSEN, A. C., POON, C., & ROMAN, B. (2017) · Forum of Mathematics, Sigma · doi:10.1017/fms.2016.32 · Cited by 256
Metadata
- Authors
- Larson, P. E. Z., Hu, S., Lustig, M., Kerr, A. B., Nelson, S. J., Kurhanewicz, J., Pauly, J. M., & Vigneron, D. B.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2010-10-11
- Volume
- 65
- Issue
- 3
- Pages
- 610-619
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2093352087
- Cited by
- 192
- References
- 2
- FWCI
- 8.92
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.